Hitachi L300P-110L Instruction Manual page 82

L300p series three phase input 200/400v class
Table of Contents

Advertisement

Intelligent input terminal setting
It is possible to operate functions by assigning those functions to the
intelligent input terminals 1-5 (C001-C005).
The intelligent input terminals 1-5 can be selected individually whether the contact input specification is either
a NO or a NC contact.
Two or more intelligent input terminals can't be assigned to be the same function.
If an intelligent input is assigned a function which is already assigned to another terminal it will automatically
be restored back to the setting before.
Function Code
Data
01
02
03
04
05
06
07
08
09
11
12
13
14
15
16
18
20
C001- C005
21
22
23
24
27
28
29
31
32
33
34
35
36
37
38
39
no
Input terminal a/b (NO/NC) selection
It is possible to set a contact input or b contact input to
intelligent input terminals 1-5 and FW terminals individually.
Set item
Function code Data
Intelligent input 1-5
C011-C015
a/b(NO/NC)selection
Input FW
a/b(NO/NC)selection
Description
RV:Reverse command
CF1:Multi-speed 1 (binary operation)
CF2:Multi-speed 2 (binary operation
CF3:Multi-speed 3 (binary operation)
CF4:Multi-speed 4 (binary operation)
JG:Jogging
DB:External DC braking
nd
SET:2
Set of Motor Data
2CH:Two-stage adjustable-speed
FRS:Free-run stop
EXT:External trip
USP:Unattended start protection
CS:Commercial change
SFT:Software lock (control terminal)
AT:analog input voltage/current select
RS:Reset inverter
STA:3 wire start
STP:3 wire stop
F/R:3 wire direction
PID:PID selection (valid/invalid)
PIDC:PID integrating reset
UP:Remote control UP function
DWN:Remote control DOWN function
UDC:Remote control data clear
OPE:force operation ope
SF1:Multi-speed 1 (bit run)
SF2:Multi-speed 2 (bit run)
SF3:Multi-speed 3 (bit run)
SF4:Multi-speed 4 (bit run)
SF5:Multi-speed 5 (bit run)
SF6:Multi-speed 6 (bit run)
SF7:Multi-speed 7 (bit run)
OLR:Overload restriction change
NO:No assign
Description
00
A contact(NO)
01
B contact(NC)
00
A contact(NO)
C019
01
B contact(NC)
Chapter 4 Explanation of function
C001-C005: Intelligent input terminal
Multi-speed operation function
Jogging operation
DC braking(external DC braking)
nd
2
Two-stage adjustable-speed function 4-32
Unattended start protection function 4-49
Commercial change
Analog external input
3 wire input function
UP/DOWN function
force operation ope function
Multi-speed operation function
Overload restriction
Relation code
C011-C015: Intelligent input a/b (NO/NC)
selection
C019
a contact: "ON" with Close, "OFF" with Open
b contact: "ON" with Open, "OFF" with Close
RS terminal can set only a contact.
4-42
Relation code
Reference item
Operation run
Set of Motor Data
Free-run stop
External trip
Software lock
Reset inverter
PID function
-
:Input FW a/b (NO/NC) selection
Page
4-14
4-43
4-44
4-26
4-45
4-46
4-50
4-47
4-45
4-19
4-48
4-50
4-30
4-49
4-55
4-43
4-38
-