Hitachi L300P-110L Instruction Manual page 39

L300p series three phase input 200/400v class
Table of Contents

Advertisement

(2) Operation setting and the frequency setting from the digital operator
(Remote Operator (SRW) is also same use.)
Three phase
Power Supply
(Arrangements)
[1] Please make sure that there isn't matter about the connection.
[2] Turn the ELB on to supply power to the inverter.
(The red LED "POWER" on the digital operator should illuminate.)
[3] Set operator with the frequency setting selection.
Set A001 as indication code, press the
(Two figures are shown.)
Set 02 with the
the operator.
(Indication code turns back to A001.)
[4] Set operator with the operation setting selection.
Set A002 as indication code, press the
(Two figures are shown.)
Set 02 with the
operator.
(Indication code turns back to A002.)
ELB
R
R
S
S
T
T
FW
5
Digital operator
1
FM
TH
CM1
PLC
P24
H
O
OI
O2
AM
AMI
L
G
key or the
key, press the
1
2
key or the
key, press the
2
1
U
Motor
V
W
PD
Direct current reactor
P
RB
Braking unit
N
AL0
AL1
Alarm output
AL2
11A
11C
12A
12C
SP
SN
RP
SN
Ground
key once.
FUNC
key once to set the frequency setting for
STR
key once.
FUNC
key once to set the operation setting for the
STR
3-5
Chapter 3 Operation