Hitachi L300P-110L Instruction Manual page 109

L300p series three phase input 200/400v class
Table of Contents

Advertisement

(vii) 06 command: This reads 1 set item.
• Transmission frame
Frame format
STX
Code
Command
Explanation
STX
Control code(Start of TeXt)
Code
Station number of inverter
Command
Transmission command
Parameter
Parameter number of data
BCC
Block check code
CR
Control code(Carriage Return)
(Note 9) The range of parameter to get,
F002-, A001-, b001-, C001-, H003-, P001-
Replay frame
Frame format
On normal reply : (4) - (i) Reference
STX
Code
ACK
Explanation
STX
Control code(Start of TeXt)
Code
Station number of inverter
ACK
Control code(ACKnowledge)
Data
Data (tenth ASCII code)
BCC
Block check code
CR
Control code(Carriage Return)
(Note 10) When data is the selected item, this transmits and receives corresponding to station number.
On abnormal reply : (4) - (ii) reference
(viii) 07 command: This sets 1 set item.
• Transmission frame
Frame format
STX
Code
Command
STX
Control code(Start of TeXt)
Code
Station number of inverter
Command
Transmission command
Parameter
Parameter number of data
Data of parameter
Data
(Tenth ASCII code)
BCC
Block check code
CR
Control code(Carriage Return)
Reply frame
On normal reply : (4) - (i) Reference
On abnormal reply : (4) - (ii) Reference
Parameter
BCC
Data size
1 byte
2 byte
2 byte
4 byte
2 byte
1 byte
Data
BCC
CR
Data size
1 byte
2 byte
1 byte
8 byte
2 byte
1 byte
Parameter
Data
Explanation
1 byte
2 byte
2 byte
4 byte
8 byte
2 byte
1 byte
Chapter 4 Explanation of function
CR
Value
STX (0x02)
01-32
06
(Note 9)
Exclusive OR of Code, Command and
Data (5) Reference
CR (0x0D)
(F001 uses 01 command.)
Value
STX (0x02)
01-32
ACK (0x06)
(Note 10)
Exclusive OR of Code, Command and
Data (5) Reference
CR (0x0D)
BCC
CR
Data size
STX (0x02)
01-32, FF(broadcast)
07
(Note 9)
(Note 10)
Exclusive OR of Code, Command and
Data (5) Reference
CR (0x0D)