L300P-220L - Hitachi L300P-110L Instruction Manual

L300p series three phase input 200/400v class
Table of Contents

Advertisement

(4) Common applicable tools
Power lines
Applicable
Motor
Inverter
Output
model
(kW)
more
11
L300P-110LF
15
L300P-150LF
(
Note 1)
18.5 L300P-185LF
22
L300P-220LF
30
L300P-300LF
(Note 1)
(38×2)
37
L300P-370LF
(Note 1)
45
L300P-450LF
(38×2)
(60×2)
55
L300P-550LF
(Note 1)
(60×2)
75
L300P-750LF
(Note 1)
11
L300P-110HF
15
L300P-150HF
18.5 L300P-185HF
22
L300P-220HF
30
L300P-300HF
37
L300P-370HF
45
L300P-450HF
55
L300P-550HF
75
L300P-750HF
(38×2)
90
L300P-900HF 38×2
L300P-
110
60×2
1100HF
L300P-
80×2
132
1320HF
#1 3/0 or 2 parallel of 1 AWG #2 250kcmil or 2 parallel of 1 AWG(75ºC) #3 350kcmil or 2 parallel of 1/0 AWG
#4 Use suitable fuse with an UL-listed for UL. #5 Conformity to the UL
(Note) Field wiring must be made by an UL-listed and CSA-certified closed-loop terminal connector sized for
the wire gauge involved. Connector must be fixed by using the crimping tool specified by the connector
manufacture or equivalent wording included in the manual.
(Note 1) If wires are shorter than 10m and are located within an enclosure, it is possible to use following power
lines.
Power lines
Inverter
2
mm
AWG
Model
or
more
more
150LF
14
300LF
38
370LF
60
550LF,750LF
100
Earth line
R,S,T,U,V,
G
W,P,PD,N
2
2
mm
mm
AWG
AWG
or
or
or
or
more
more
more
14
4
14
4
22
2
22
3
30
1
22
3
38
1/0
30
2
60
2/0
30
2
100
(#1)
50
1/0
100
(#2)
80
3/0
150
(#3)
80
3/0
150
(#3)
100
4/0
5.5
8
5.5
8
8
6
8
8
14
6
14
4
14
4
14
4
22
3
22
3
38
1
22
3
38
1
22
1
60
1/0
30
1
100
50
1/0
(#2)
(#2)
50
3/0
(#3)
80
3/0
(#3)
100
4/0
Terminal
Heat
or
resistant
4
110ºC
14-6
1/0
110ºC
38-8
2/0
110ºC
60-8
(#2)
110ºC
100-10
Chapter 2 Installation and Wiring
Chapter 2 Installation and Wiring
External
resister
between
P and RB
Screw
size of
Terminal
AWG
terminal
or
2
mm
AWG
more
#5
(
)
10
5.5
8
M6
8
5.5
8
M6
8
-
-
M6
8
-
-
M8
6
-
-
M8
6
-
-
M8
100-10
6
-
-
M10
(38-10)
150-10
4
-
-
M10
(60-10)
150-10
4
-
-
M10
(60-10)
10
5.5
8
M6
10
5.5
8
M6
10
-
-
M6
10
-
-
M6
10
-
-
M6
8
-
-
M6
8
-
-
M8
6
-
-
M8
6
-
-
M8
6
-
-
M10
4
-
-
M10
4
-
-
M10
2-12
Applicable tools
Tightning
Torque
max
Leak breaker
(N•m)
(ELB)
14-6
4.9
RX100(75A)
22-6
4.9
RX100(100A)
38-6
4.9
RX100(100A)
38-8
8.8
RX225B(150A)
60-8
8.8
RX225B(200A)
100-8
8.8
RX225B(225A)
(38-8)
13.7
RX225B(225A)
13.7
RX400B(350A)
13.7
RX400B(350A)
5.5-6
4.9
EX50C(50A)
8-6
4.9
EX60B(60A)
14-6
4.9
EX60B(60A)
14-6
4.9
RX100(75A)
22-6
4.9
RX100(100A)
38-6
4.9
RX100(100A)
38-8
8.8
RX225B(150A)
60-8
8.8
RX225B(175A)
100-8
8.8
RX225B(225A)
(38-8)
38-10
13.7
RX225B(225A)
60-10
13.7
RX400B(350A)
80-10
13.7
RX400B(350A)
Electro-
Circuit
magnetic
breaker
controller
or fuse
(Mg)
60A
H50
70A
H65
90A
H80
100A
H100
150A
H125
175A
H150
200A
H200
250A
H250
300A
H300
30A
H25
35A
H35
50A
H50
50A
H50
70A
H65
80A
H80
100A
H100
125A
H125
150A
H150
200A
H200
250A
H250
300A
H300

Advertisement

Table of Contents
loading

Table of Contents