CALIBRATION NOTES & INSTRUCTIONS- CONT'D
"Bypass Speed", this is the pump duty cycle value, 1-10, to adjust the "Hot water
Bypass", or hot water speed during machine cycles. Note: too high a value may result in
water overflow, too low a value and water will trickle out of machine. Value is set at 4
at the factory.
[HOT WATER PUMP]
"Bypass Cal", Insert a container capable of holding 32 or more ounces of water under
delivery area of machine, then press the top left button to start calibration countdown
period of 30 seconds. (Note: if machine is not up to temperature, machine will wait until
temperature is reached before running calibration cycle, display will read "Preparing to
Brew" At the end of the calibration cycle, display will change to "Adjust Value". Use the
upper left buttons to toggle the value, increasing or decreasing value until the display
number matches the amount of water measured in ounces (see instruction #5 pg. 17).
Press the Upper Right button when done- screen will change to "Bypass Cal" again.
This is in case there was a spill or problem during the cycle and the measurement
needs to be repeated- to repeat press the top right button to restart cycle.
WATER PUMP]
"Mix Bowl Cal", Insert a container capable of holding 32 or more ounces of water
under delivery area of machine, then press the top left button to start calibration
countdown period of 30 seconds. (Note: if machine is not up to temperature, machine
will wait until temperature is reached before running calibration cycle, display will read
"Preparing to Brew") At the end of the calibration cycle, display will change to "Adjust
Mix bowl Cal" This Number will need to be within ½ ounce of 20 ounces, (see
instruction #5 pg. 17). Press the Upper Right button when done- screen will change to
"Mix Bowl Cal" again. This is in case there was a spill or problem during the cycle and
the measurement needs to be repeated- - to repeat press the top right button to restart
cycle. Note: When replacing Mix Bowl Dispense (Dump) valve, the valve must be
adjusted to dispense 20
(+/- ½) ounces in this calibration cycle. See Illustrations Below.
SET TO 20 OUNCES]
Mix Valve
(Dump Valve)
Location
Rear view of Machine
with RH Cover
Removed
Flow Adjustment Fitting (7/32" or
6mm Allen or 5/16" Flat Blade
Screwdriver)
[HOT
[DUMP VALVE
18