Service Notes & Troubleshooting
MACHINE CALIBRATION
NOTE:
THIS MACHINE HAS BEEN CALIBRATED AT THE FACTORY,
AND CHANGING THESE SETTINGS CAN AFFECT THE QUALITY OF
THE DRINK. ANY CHANGE TO THESE SETTINGS MUST BE DONE BY
TRAINED SERVICE PERSONELL ONLY.
To Access Calibration Menu:
Machine Power On
CALIBRATION
1. Press Button to Select "Calibration"
2. Toggle Selection to be calibrated
3. Select to run calibration
4. Press Button To Toggle Display
• Bypass Speed 0-10
• Bypass Calibration Value (Ounces)
• Mix Bowl Calibration Value (Ounces)
• Left Auger Speed 0-10
• Left Auger Calibration Value in grams
• Right Auger Speed 0-10
• Right Auger Calibration Value in grams
• Coffee POD Calibration Value (Ounces)
• Tea POD Calibration Value (Ounces)
• Flow Meter Adjust
• Flow Meter Test
• Exit Calibration
5. Use To Change Values Up Or Down
NOTE:
SHOULD THE COFFEE OR TEA
VOLUME NEED ADJUSTMENT, A SMALL
VOLUME CAN BE ADDED OR SUBRACTED
BY ADJUSTING THE "FLOWMETER ADJ"
VALUE + OR -
Hold Lower LH Button Down While Turning
Factory Defaults
Bypass Speed
Bypass Cal
Left Auger Speed
Left Auger Cal
Right Auger Speed
Right Auger Cal
Mix Bowl Cal
Value
4
20.0
9
156
9
90
20.0
17