Page 1
DB2A INSTALLATION REV 3-29-2006 DUAL BREWER AUTOMATIC DB2A INSTALLATION, OPERATION, AND TROUBLESHOOTING MANUAL FOR DB2A AUTOMATIC BREWER WITH WARMERS & POUR-OVER Model DB2A 8-1/2 W x 18 D x 33 H 4700 Total Watts, 23.3 AMPS 120/208 V Ship Wt approx. 54 LB’s...
Page 4
PLUMBER'S INSTALLATION INSTRUCTIONS CAUTION:Disconnect Power to brewer before proceeding with plumbing installation. Attach water line to bottom PDS valve , rear of brewer . Flush water line before installing brewer. Brewer should be connected to COLD WATER LINE for best operation. Water pressure should be at least 40 lbs.
Page 5
Deliming spring will not go in overflow orifice. (see diagram below) Sprayhead Overflow outlet orifice DELIMING SPRING PN 120127 (INCLUDED) WARRANTY Refer to Warranty Agreement between TDL Group, BBC Sales, and Newco Enterprises.
TROUBLE SHOOTING GUIDE SYMPTOM POSSIBLE WHAT TO REMEDY CAUSE CHECK CAN'T START BREW CYCLE 1. No water. 1. Incoming water lines & water shut 1. Be sure water shut off is open. off valve. 2. No power. 2. Fuse or circuit breaker. 2.
Page 7
TROUBLE SHOOTING GUIDE SYMPTOM POSSIBLE WHAT TO REMEDY CAUSE CHECK IRREGULAR YIELD 1. Not siphoning properly. 1. Refer to "DRIPPING", Step 1. 1. Refer to "DRIPPING", Step 1. 2. Timer. 2. Timer consistency. Time several 2. If times are irregular, replace timer. brew cycles.