Page 1
HP Agilent 16823A Manual Get Pricing & Availability at ApexWaves.com Call Today: 1-800-915-6216 Email: sales@apexwaves.com https://www.apexwaves.com/analyzers/keysight-technologies/16800-series/16823A...
Page 2
Keysight 16800 Series Portable Logic Analyzers Installation/ Quick Start Guide REPRODUCTION AND DISTRIBUTION OF THIS TECHNICAL MANUAL IS AUTHORIZED FOR GOVERNMENT PURPOSES.
Page 3
FAR 2.101(a) or as "Restricted computer software" as defined in FAR 52.227-19 (June 1987) or any equivalent agency regulation or contract clause. Use, duplication or disclosure of Software is Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Page 4
16800 Series Logic Analyzers—At a Glance The Keysight Technologies 16800 Series logic analyzers are portable logic analyzers that range from 34 to 204 logic acquisition channels and 48 pattern generator channels, depending on the model. Table 1 Model comparisons Keysight model number...
Page 5
Logic Analyzers with the serial number of MY51420101 or higher have Windows 7 installation. • Keysight Logic Analyzer application which takes the complexity out of making logic analyzer measurements. You can perform all operations directly from one window. Features, Pattern Generator •...
Page 6
Before you turn on the system, connect your mouse and keyboard to the 16800 Series logic analyzer rear panel. If a touch screen (Option 103) is not included, a connected mouse and keyboard are required for normal system use. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Page 7
Firewall settings. It also describes how to get and install software updates. Solving Problems This chapter describes the logic analyzer’s built-in self tests and recovering system software. Safety Notices This chapter contains additional safety information. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Protecting the Instrument’s Operating System 2 Getting Started with the Logic Analyzer Probing Making a Measurement Snap to Edge Markers Left-Click Menus Tree Structure Bus/Signal Names Offline Analysis Marker Overview Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Page 9
If the Power LEDs do not come on If you get a registry error and the system won’t boot If there are network connection problems If there are touch screen problems Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Page 10
On a Legacy 16800 Series Logic Analyzer with Windows XP Installation On a 16800 Series Logic Analyzer with Windows 7 Installation Contacting Keysight Service/Support 5 Safety Notices Warnings To clean the instrument Safety Symbols Index Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide First-Time Set Up Proper Cooling / 12 First-Time Set Up Considerations / 13 First-Time Set Up On Legacy 16800 Series Logic Analyzers With Windows XP Installation / 14 First-Time Set Up On 16800 Series Logic Analyzers with Windows 7...
First-Time Set Up Proper Cooling Allow at least 5 cm (2 inches) of space between instruments for proper cooling. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
The Workgroup or Domain name. • Methodology for assigning IP addresses at your site (for example, DHCP). • Domain Name Service (DNS). Other network information that may be readily available from your network administrator. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
(less than 15 characters, etc.) question to appear) What's your administrator password? Keysight recommends entering an administrator password for administrator accounts. See page 18 actions that require administrator accounts. Is this computer in a domain?
“Is this computer in a domain?”, may not appear. If this occurs, you need to change the logic analyzer’s network setup (after the first-time power up) using the normal Windows XP methods (see “Changing Network Settings" on page 34). Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
If your organization has a standard naming scheme, use that scheme. Otherwise, choose a descriptive name (less than 15 characters) Specify the administrator password Keysight recommends entering an administrator password for administrator accounts. See page 18 actions that require administrator accounts.
Page 18
This registration is to allow Microsoft to contact you. Specify users for the instrument’s PC You can add multiple users with administrator permissions to allow these users to use the logic analyzer. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Additional First-Time Setup Steps Establishing an Administrator Account (recommended for standalone and networked instru- ments) Keysight recommends that you set up an Administrator account for your logic analyzer. You have to be logged in to the Administrator account to do the following: •...
Getting Started with the Logic Analyzer Probing Probing is the key to effective and efficient use of logic analyzers. Keysight Technologies offers a wide variety of probing accessories that support general-purpose and application-specific measurement needs. We provide reliable, electrically and mechanically unobtrusive probes that make it easy to connect your Keysight logic analyzer to your system under test.
Getting Started with the Logic Analyzer Making a Measurement Start up the logic analyzer, connect to your target system, and select Setup>Bus/Signal. Assign buses and signals and click OK. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Page 23
Getting Started with the Logic Analyzer Enter a trigger value. Acquire and view data. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Getting Started with the Logic Analyzer Snap to Edge Markers You can set the markers to jump to the nearest edge of a waveform. A yellow target will show which edge the marker will jump to. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Drag a box around parts of the data. When you release the mouse button, a menu appears. Tree Structure Bus/Signal Names Show individual signals in buses by clicking on the + to expand. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Getting Started with the Logic Analyzer Offline Analysis Install the Keysight Logic Analyzer application on another Windows XP, Windows 7, or Windows 2000 computer and you can analyze data without the 16800 Series logic analyzer. Follow the instructions in “Software Installation and Upgrades"...
Getting Started with the Logic Analyzer Tool Tips Pause the cursor over a tool Icon and a “Tool Tip Window” will appear. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Getting Started with the Logic Analyzer Trigger History Save and recall trigger settings. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Clicking the 'yes' button results in the above events. Clicking 'no' will prevent the shutdown. Not answering the dialog box (clicking neither “Yes” nor “No”) will have no effect. Further short presses on the power button will have no effect. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Unplugging power or a power loss is similar to the long press of the power button with one exception: • When the system is plugged back in, it will power up and boot into Windows. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Keysight 16800 Series logic analyzers. Electrical Characteristics Power Requirements 16801A, 16802A, and 16803A: 115/230 Vac +/- 20%, 48-66Hz, 615W Max. 16804A, 16806A, 16821A, 16822A, and 16823A: 115/230 Vac +/- 20%, 48-66Hz, 775W Max. CAT II (Line voltage in appliance and to wall outlet).
Page 32
Getting Started with the Logic Analyzer Click Reference; then, click Specifications and Characteristics. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Page 33
Getting Started with the Logic Analyzer Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Panel>Network and Sharing Center. Select the connection you want to change and then set the properties of this connection. For more information on changing network settings, refer to the Windows 7 online help. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Use RealVNC to remotely control the logic analyzer. On Windows XP To change firewall settings to give other applications/ports access: From the Windows Start menu, choose Start>Control Panel. In the Control Panel window, open Windows Firewall. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Page 37
The list of allowed programs and features is displayed. If the required program or service is listed, check its box to enable it; otherwise, click Allow another program... to give unlisted programs permission to penetrate the firewall. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
To restore the logic analyzer firewall defaults On legacy 16800 logic analyzers From the Windows Start menu, choose Start>Control Panel. In the Control Panel window, open Windows Firewall. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Page 39
Windows XP installation, then restore the firewall defaults by following the steps 1 to 6 in the procedure described in previous section. After that, uninstall and then reinstall the Logic Analyzer software from www.keysight.com/find/la-sw-download. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Page 40
Note that there are separate Windows Firewall profiles: Domain for when NOTE the computer has domain membership, and Standard for when the computer has workgroup membership. When you restore the logic analyzer firewall defaults, the defaults for both profiles are restored. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
These systems are not shipped with an application CD. You need the Keysight Logic Analyzer software version 5.20 or later for these systems. Note that newer versions of the Keysight Logic Analyzer software will automatically uninstall the previous version as a step in the upgrade.
Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide Solving Problems Running Self-Tests / 42 If the logic analyzer powers itself down / 43 If the Power LEDs do not come on / 43 If you get a registry error and the system won’t boot / 43...
Solving Problems Running Self-Tests 1 In the Keysight logic analyzer application, click Help>Sel f Test. 2 In the analysis system Self Test dialog, double click on the test you want to run. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
2 Mount it under another Windows XP/7 system based on which operating system is installed on the Logic Analysis system. 3 Move the data to the boot disk until you can restore the operating system. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
See the “Network Troubleshooting Guide” topic in the Keysight Logic and Protocol Analyzer application’s online help. Briefly: • The Windows Firewall must be set to allow access to the “Keysight Logic Analysis” service in order use remote connections (see “To restore the logic analyzer firewall defaults"...
16800 series of logic analyzers. On legacy 16800 series logic analyzers: 1 From the Windows Start menu, choose Start>All Programs>Keysight Logic Analyzer>Utilities>Touch Screen >Settings. 2 In the UPDD Console dialog, select the Calibration settings area.
Page 47
Click Settings tab and then select the Enable Right-Click checkbox. You can also set the area on the touch screen on which you want to enable the right-click functionality. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Page 48
Solving Problems If calibrating the touch screen doesn’t fix the problem, see “Contacting Keysight Service/Support" on page 53. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
On a Legacy 16800 Series Logic Analyzer with Windows XP Installation The legacy 16800 series of Logic Analyzers have the Windows XP operating system installed. These systems also have the Keysight Logic Analyzer software preinstalled. You need to have a keyboard, mouse, and USB DVD-ROM drive connected.
Page 50
If this happens, the restored license files will not work with the new host ID and you will need rehosted license files. To get these files, you can contact your nearest Keysight sales/service office. To locate a sales or service office, go to www.keysight.com/find/contactus.
Page 51
1 to run Check Disk on the Logic Analyzer’s hard disk drive. If the recovery process encounters any problems while running Check Disk, it reports these problems else it returns to the Keysight Recovery system prompt on completion of Check Disk.
Page 52
C: drive. If you want to save your data to a CD or to another machine before you proceed further, then exit the recovery process and save your data. Else, click OK to proceed with the recovery process. The recovery process starts. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Page 53
6 The Windows Boot Manager screen is displayed with Microsoft Windows 7 as the default selection. The system automatically starts with this default selection. Alternatively, you can press Enter to proceed with the default selection. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
In such situations, you can send your Logic Analysis system for hard disk repair/replacement to Keysight. Alternatively, you can contact your nearest Keysight sales/service office. To locate a sales or service office, go to www.keysight.com/find/contactus. Contacting Keysight Service/Support To locate a sales or service office near you, go to: http://www.keysight.com/find/contactus...
Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide Safety Notices Warnings / 56 To clean the instrument / 57 Safety Symbols / 58 This apparatus has been designed and tested in accordance with IEC Publication 1010, Safety Requirements for Measuring Apparatus, and has been supplied in a safe condition.
Refer to http://www.keysight.com/quality/Working_In_Comfort.pdf for set-up and use recommendations • Position equipment so that it is not difficult to disconnect the power cord. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Clean the external surfaces of the instrument with a soft cloth dampened with a mixture of mild detergent and water. Make sure that the instrument is completely dry before reconnecting it to a power source. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Hazardous voltage symbol. Earth terminal symbol: Used to indicate a circuit common connected to grounded chassis. Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Page 60
System recovery on Windows 7 network settings, installation, firewall, changing settings, 18, optional tools, tools, optional, touchscreen problems, grounding, password, Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Page 61
Index update software, virus software, windows power problems, updates, welcome, welcome questions, Windows Boot Manager, Windows Firewall settings changing, workgroup, changing, Keysight 16800 Series Portable Logic Analyzers Installation/Quick Start Guide...
Need help?
Do you have a question about the 16801A and is the answer not in the manual?
Questions and answers