4.1.8

Calculation example

A transport system moves pallets with transponders at a maximum velocity of V
m/s. The following RFID components were chosen:
• 8xIQ-Sense module
• RF 310-R reader
• RF 340-T transponder
Task specification
a) The designer of the plant is to be given mechanical specifications.
b) The programmer should be given the maximum number of words in dynamic mode.
Refer to the tables in the "Field data of transponders and readers" section for the technical
data.
RF 300
System Manual, 05/2005, (4)J31069 D0166-U001-A1-7618, --
RF 300 system planning
4.1 Fundamentals of application planning
= 0.14
TPDR
4-9