SIMATIC Sensors
RFID systems
SIMATIC RF382R Scanmode
Operating Instructions (Compact)
Characteristics
RF382R Scanmode
Ordering data
Table 1 RF382R Scanmode ordering data
Product
RF382R Scanmode
Table 2 RF382R Scanmode ordering data for accessories
Accessories
Simatic Sensors connecting cable, length: 5 m
Simatic Sensors RF380R connecting cable RS232
Wide-range power supply 24 V, 4 A, with Euro plug
Wide-range power supply 24 V, 4 A, with UK plug
Wide-range power supply 24 V, 4 A, with US plug
Safety instructions for the device/system
NOTICE
This device/system may only be used for the application instances that have been described in the catalog and the
technical documentation "SIMATIC RF300 System Manual
(http://support.automation.siemens.com/WW/view/en/21738946)" and only in combination with third-party devices and
components recommended and/or approved by Siemens.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the
equipment
© Siemens Ⓟ 2009
J31069-D0214-U001-A1-7618, 10/2009
Characteristics
Operating range
Antenna field
Read distance
Degree of protection
Suitable for high speeds, e.g. in
● Suspension conveyor systems
● Assembly lines
● Production
● Order picking
Designed for transponders that are directed
sideways past the long side of the antenna.
See Chapter Transmission window (Page 3)
Depending on transponder; see Field data for
MDS and SLG (Page 6)
IP67
Order No.
6GT2801-3AB20-0AX0
‎Order No.
6GT2891-0FH50
6GT2891-0KH50
6GT2898-0AA00
6GT2898-0AA10
6GT2898-0AA20
1

Advertisement

Table of Contents
loading

Summary of Contents for Siemens Simatic RF382R Scanmode

  • Page 1 This device/system may only be used for the application instances that have been described in the catalog and the technical documentation "SIMATIC RF300 System Manual (http://support.automation.siemens.com/WW/view/en/21738946)" and only in combination with third-party devices and components recommended and/or approved by Siemens.
  • Page 2: Display Elements Of The Rf382R Scanmode Reader

    Operating voltage present, reader ready for operation Yellow Transponder present Red LED for error display is activated permanently if correct operation of the reader cannot be guaranteed (e. g. faulty start, checksum error during operation). SIMATIC RF382R Scanmode J31069-D0214-U001-A1-7618, 10/2009...
  • Page 3: Transmission Window

    Transmission window Orientation of magnetic fields of the SIMATIC RF382R Scanmode For many applications it may be best to operate the reader so that the tags move from left to right (or from right to left) at a certain distance in front of the narrow edge of the reader. This direction of movement uses the horizontal magnetic field of the reader, see figure below.
  • Page 4 The operating range between Levels ① and ② includes secondary fields. The recommended operating range therefore lies in the green main field between Level 2 and Level 3. Limit distance (S The limit distance lies on Level ③. SIMATIC RF382R Scanmode J31069-D0214-U001-A1-7618, 10/2009...
  • Page 5 Maximum length of the main field, horizontal magnetic field Distance from the reader edge at which maximum horizontal main field length L exists Operating range in the main field Limit distance = 13 mm ⇓ Direction of motion of the transponder SIMATIC RF382R Scanmode J31069-D0214-U001-A1-7618, 10/2009...
  • Page 6: Field Data For Mds And Slg

    Field data for MDS and SLG The following tables show the field data of transponders with SIMATIC RF382R Scanmode. The technical specifications listed below are typical data and apply at an ambient temperature of +22 °C. Tolerances of ±20% are admissible due to production and temperature conditions.
  • Page 7 If the distance values specified in the tables are undershot, it is possible that the inductive fields will be affected. The time required for data transmission can increase unpredictably. For this reason, please observe the values in the tables. SIMATIC RF382R Scanmode J31069-D0214-U001-A1-7618, 10/2009...
  • Page 8: Traversing Speed With Rf382R Scanmode

    The RF382R can be mounted directly on metal. Flush mounting on metal is not permitted. Minimum distance between several RF382R Scanmode readers Figure 6 Minimum distance between several RF382R Scanmode readers Minimum distance D from RF382R to RF382R D ≥ 200 mm SIMATIC RF382R Scanmode J31069-D0214-U001-A1-7618, 10/2009...
  • Page 9: Setting The Parameters Of The Rf382R

    The BCC value in the parameter message frame is incorrect. Data could not be saved retentively (error with Flash type request) Data could not be saved retentively (error with Flash delete) Data could not be saved retentively (error with Flash writing) SIMATIC RF382R Scanmode J31069-D0214-U001-A1-7618, 10/2009...
  • Page 10: Technical Specifications

    Weight approx. 550 g MTBF (Mean Time Between Failures) 1 x 10 Approvals Radio to R&TTE guidelines EN 300 330, EN 301489, CE Current consumption typ. 140 mA Max. power consumption (DC input) 3.5 W SIMATIC RF382R Scanmode J31069-D0214-U001-A1-7618, 10/2009...
  • Page 11: Dimension Drawing

    Support homepage (www.siemens.com/automation/service&support) RFID homepage For general information about our identification systems, visit RFID homepage (www.siemens.com/simatic-sensors/rf). FCC Information to the user: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.