RF 300 system planning
4.4 Installation guidelines
The impact of metal on the field data (S
this section. The values in the table describe the reduction of the field data in % with
reference to non-metal (100 % means no impact).
Reduction of field data: Transponder and Reader RF 310-R
Table 4-1
Transponder
RF 320-T
Transponder without metal
Transponder on metal,
distance 20 mm
Flush-mounted in metal
RF 340-T
Transponder without metal
Transponder on metal, distance 20
mm
Flush-mounted in metal
distance 20 mm/
20 mm surround
4-20
Reduction of field data by metal (in %): Transponder and RF 310-R
, S
, L, B) is shown in tabular and graphical format in
g
a
Reader RF 310-R
without metal
on metal
100
100
80
100
100
90
System Manual, 05/2005, (4)J31069 D0166-U001-A1-7618, --
flush-mounted
in metal
(20 mm surround)
95
80
80
70
70
60
95
80
95
80
85
70
RF 300