E52: No Signal From The Motor Tachometric Generator (Second Part); Fig. 11; If There Are Traces Of Burning On The Circuit Board, Refer To Pages - Electrolux EWM25 series Service Manual

Washing machines & washer-dryers
Hide thumbs Also See for EWM25 series:
Table of Contents

Advertisement

E52: No signal from the motor tachometric generator (second part)

E52
Cycle blocked after 5 attempts during the cycle or immediately if
Checks to perform:
The motor does not rotate at all
To check the wiring, measure (Ω) across
the following terminals of the circuit board
connector (fig. 35) and compare with the
correct values.
(see page 59: step 4 – motor parameters)
- across J2-6 and J2-7, the value must
be as in 4 - B (stator)
- across J2-5 and J2-6, if present, the
value must be as in step 4 - C (stator)
- across J2-5 and J2-7, the value must
be as in step 4-D (stator).
Are these values correct?
Replace the motor circuit board and
restart the diagnostic cycle to check
for further alarms.

Fig. 11

07-2010 SOI/DT-mdm FCPD-dp Quality-fz
Check that all the connectors are inserted correctly
YES
detected at the start or during
diagnostics.
Check the motor
NO
as described on
page 59.
Is the motor OK?
YES
Check/replace the wiring and restart the
diagnostic cycle to check for further alarms.
J6
J2
If there are traces of burning on the
circuit board, refer to pages
58/121
Replace the motor
and restart the
NO
diagnostic cycle to
check for further
alarms.
J2
J6
J1
Motor circuit board
E52
Fig. 35
J1
119-120
599 70 99-00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ewm35 series

Table of Contents