Ed1: Communication Problems Betweeen Main Circuit Board And Wd Board - Electrolux EWM25 series Service Manual

Washing machines & washer-dryers
Hide thumbs Also See for EWM25 series:
Table of Contents

Advertisement

ED1: Communication problems betweeen main circuit board and
Ed1
Checks to perform:
Measure the continuity
between connector J16
(main circuit board) and
J1 (WD board).
Is the wiring OK?
YES
Replace the WD board
and restart the
diagnostic cycle to
check for further
alarms.
If the alarm appears again, replace
the main circuit board and restart
the diagnostic cycle to check for
further alarms.
07-2010 SOI/DT-mdm FCPD-dp Quality-fz
WD board
Check that all the connectors are inserted correctly
Replace the wiring and
restart the diagnostic
NO
cycle to check for
further alarms.
WD
board
Main circuit
If there are traces of burning on the
circuit board, refer to pages
97/121
board
119-120
599 70 99-00
Ed1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ewm35 series

Table of Contents