E9F: Communication error between main board and Inverter board

E9F
Checks to perform:
Measure the continuity
between the connector
J18 (main board) and
J6 (Inverter board).
Is the wiring ok?
YES
Replace the Inverter
board and restart the
diagnostic cycle to
check for further
alarms.
If the alarm appears again, replace the main board
and restart the diagnostic cycle to check for further
07-2010 SOI/DT-mdm FCPD-dp Quality-fz
Check that all the connectors are inserted correctly
Replace the wiring and
NO
restart the diagnostic
cycle to check for
further alarms.
alarms.
0
If there are traces of burning on the
circuit board, refer to pages
Circuit
board
Motor circuit board
88/121
E9F
119-120