Zone Inputs; Keypad Installation; Keypad Zone Installation; Keypad Tamper - Paradox SPECTRA 1727 Installation Manual

Hide thumbs Also See for SPECTRA 1727:
Table of Contents

Advertisement

PGM Event
Exit Delay
Armed
Ready
"PG" Key
Fire Alarm
Audible Alarm
Strobe
Entry Delay/Exit Delay/Alarm
Exit Delay/Armed
Entry Delay/Alarm
Regular Armed
PGM 1 Events
Option
First Digit
[0]
Exit Delay
[1]
Armed
[2]
Ready
[3]
"PG" Key
[4]
Fire Alarm
[5]
Alarm
[6]
Strobe
[7]
Entry Delay/Exit Delay/Alarm
[8]
Exit Delay/Armed
[9]
Regular Arming
2.8

ZONE INPUTS

Detection devices such as motion detectors and door contacts are connected to the control panel's zone input terminals labelled Z1, Z2, Z3, Z4
and
as shown in Figure 8-2: Zone Connections on page 14. Once the zones are connected, the associated zone's parameters must be
FIRE
defined. For more information, please refer to
The
input, which is recognized as zone 6, can be connected as a fire zone or a 24-hour burglary zone. Fire zones must use a 1k
FIRE
resistor. If a line short occurs or if the smoke detector becomes active, whether the system is armed or disarmed, the control panel will generate
an alarm on this zone.
2.9

KEYPAD INSTALLATION

Only the 1686V and the 1686H Spectra Keypads are compatible with the Spectra 1727 control panel. Remove the keypad's back cover and wire
the
,
,
, and
GRN
YEL
RED
2.10

KEYPAD ZONE INSTALLATION

The keypad has one zone input terminal that allows you to connect one motion detector or one door contact directly to the keypad. The keypad
zone is recognized as zone 5. Only one keypad zone can be used per Spectra 1727 control panel. The keypad communicates the status of the
keypad zone to the control panel once the device is connected as shown in Figure 8-1: PCB Layout on page 13 and the zone's parameters are
defined (see section 3.2). For example, a door contact located at the front door can be wired directly to the input terminal of the keypad instead of
wiring it back to the control panel.
2.11

KEYPAD TAMPER

If the keypad has a tamper switch, the state of the tamper is displayed on zone 5. The control panel cannot differentiate between the open
keypad zone and an open keypad tamper.
4 Complete Installation Manual
The PGM activates during the Exit Delay.
The PGM activates while the system is armed.
The PGM activates while the
The PGM activates when the
The PGM activates during a Fire Alarm.
The PGM activates during any alarm.
The PGM activates while the
The PGM activates during the Entry Delay, the Exit Delay and during an alarm.
The PGM activates during the Exit Delay or while the system is armed.
The PGM activates during the Entry Delay or during an alarm.
The PGM activates while the system is Regular Armed.
Table 2: PGM Options
Zone Programming
terminals to the corresponding terminals on the control panel as shown in Figure 8-1: PCB Layout on page 13.
BLK
Table 1: PGM Events
Description
READY
LED is illuminated.
PG
key is pressed and deactivates when the key is pressed again.
ARM
LED flashes in alarm.
PGM 2 Events
Second Digit
Exit Delay
Armed
Ready
"PG" Key
Fire Alarm
Alarm
Strobe
Entry Delay/Exit Delay/Alarm
Entry Delay/Alarm
Entry Delay/Alarm
on page 5.
EOL