We hope this product performs to your complete satisfaction. Should you have any
questions or comments, please visit www.paradox.com and send us your comments.
MG5000
MG5050
SP5500
SP6000
SP7000

User Guide

Advertisement

Table of Contents
loading

Summary of Contents for Paradox MG5000

  • Page 1: User Guide

    MG5000 MG5050 SP5500 SP6000 SP7000 User Guide We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us your comments.
  • Page 2: User Settings

    User Settings For security reasons, write only the user’s name and not his or her access code. 4-Digit Codes 6-Digit Codes User # and Name Partition 1 or 2 Stay Force Arm Only PGM Only Duress 001: Master_______________________________ 1 & 2 002: Master1______________________________ 003: Master2______________________________ 004:_____________________________________...
  • Page 3: Master Quick Menus

    Master Quick Menus User Step Action Details The [ ] key will flash. LED/key on = programmed user. ] + [ MASTER CODE ] may also be used. PARTITION MASTER CODE MG32LRF/MG32LED/MG32LCD =2 digits: 01 to 32 USER NUMBER MG10LEDV/H = 1 digit: 1 to 0(10) Enter 4- or 6-digit code.
  • Page 4: Test Report

    Communicator Step Action Details The [ ] key will flash. [ ] may also be used. ] + [ PARTITION MASTER CODE MASTER CODE [3] = Personal Phone #1 [4] = Personal Phone #2 [5] = Personal Phone #3 [6] = Personal Phone #4 [7] = Personal Phone #5 [8] = Pager # #] + [...
  • Page 5: Table Of Contents

    Table of Contents User Settings ............. 0 System Features..........12 Master Quick Menus.......... 1 Display Mode........... 12 Alarm Display ..........12 Overview..............4 Fire Alarms ............12 Basic Operations ..........4 Panic Alarms ........... 12 StayD Mode ............7 Programming Chime Zones......13 To Turn On/Off StayD Mode......
  • Page 6: Overview

    Overview Thank you for selecting a security system from Paradox Security Systems Ltd. This advanced technology security system provides you with reliable security protection and powerful features that anyone can use without memorizing complex and confusing codes. The system consists of the control panel, one or more keypad modules, various input devices (e.g. motion detectors, door contacts, etc.) and various output devices (e.g.
  • Page 7 Figure 2: MG32LED (32-zone LED Keypad Module) Zone Display: Arm (red), Sleep (yel), Stay (grn): On = Partition armed The numbers [1] to [32] correspond Off = Partition disarmed to zones 1 to 32 respectively. Open Flash = Exit Delay or entry delay zones are illuminated, Fast Flash*= Exit Delay (final 10 sec.) Partition 1 Status...
  • Page 8 Figure 4: MG32LCD (32-zone Wireless LCD Keypad Module) Indicator Lights Keys = Press once + [ ] for Quick Menu Power light (yel) MASTER CODE = Power on programming = Power off = Press & hold for keypad settings StayD light (grn) On = StayD mode enabled = Press &...
  • Page 9: Stayd Mode

    StayD Mode To Turn On/Off StayD Mode To turn on StayD mode: ] + [C ] + [S StayD light on Press the [ ] key followed by a valid code, then press the [ ] key again within ten seconds. The StayD light will light up to confirm STAY STAY StayD activation, and the system will be in Stay mode.
  • Page 10: Access Codes

    Access Codes Programming Access Codes Access codes are personal identification numbers that allow you to enter certain programming modes, arm or disarm your system as well as activate or deactivate PGMs. The system supports the following: • 1 System Master Code •...
  • Page 11: Arming & Disarming

    Arming & Disarming Take full advantage of your system by familiarizing yourself with all the arming methods. If your system is not partitioned (see Partitioning on page 6), everything is considered as belonging to Partition 1. If you cannot arm because a zone is open, the system will enter in Bypass Programming. Enter the two digit zone you wish to bypass and press ], or press [ ] to bypass all open zones.
  • Page 12: One-Touch Arming

    One-Touch Arming One-Touch arming allows you to arm the system without using an access code. This feature must be enabled by your installer. If One-Touch Arming is programmed, you can increase the security level of your system (from Disarm Stay Arm Sleep Arm Full Arm) without a code.
  • Page 13: Disarming & Deactivating An Alarm

    How do I temporarily disable the Auto-Arm Timer? 1 Press the [ ] key. 2 Enter [ MASTER CODE 3 Press the [ ] key. The [ ] key will flash to indicate you are in the System Options menu. 4 Press key [1] to set partition 1, or press key [2] to set partition 2.
  • Page 14: System Features

    System Features Display Mode (MG32LRF only) The MG32LRF has two display modes. By default, the keypad will show all events (e.g. zones in alarm, bypassed zones, etc.) live as they occur. Alternatively, the system can be programmed by your installer to only display zones that cause an alarm or entry delay. If you want to see the status of all zones, press the [ ] key.
  • Page 15: Programming Chime Zones

    Programming Chime Zones A Chime-enabled zone will advise you every time it is opened by causing your keypad to beep. Each keypad must be chimed separately. How do I chime zones? MG32LED / MG32LRF (32-zone hardwired & wireless LED keypad modules only) 1 Press &...
  • Page 16: Power Save Mode (Mg32Lrf Only)

    Power Save Mode (MG32LRF only) If there is power loss on the wireless keypad, the module’s display will shut off and go into power save mode after one minute. Press the ] key to activate the display. Trouble Display Your alarm system continuously monitors several trouble conditions that can be reported directly to your monitoring station. When a trouble condition occurs, the [ ] key will illuminate.
  • Page 17: Advanced Features

    Advanced Features Quick Function Keys Upon request of your installer or monitoring station you may have to perform one of the following. To enter Menu Programming, press [ ] and then enter your [ ]. In Menu programming, press: MASTER CODE Test Report ] + [2] If your system is monitored by a monitoring station, this feature will send a test report code to the monitoring station.
  • Page 18: System Checklist

    System Checklist Partition Zone # and Description Stay Sleep Force 24Hr Entry Delay Fire Zone/Delay 1 or 2 Fire Zone? Y 01:___________________________________ ______ Delayed? Y Fire Zone? Y 02:___________________________________ ______ Delayed? Y Fire Zone? Y 03:___________________________________ ______ Delayed? Y Fire Zone? Y 04:___________________________________ ______ Delayed? Y...
  • Page 19: Zone Description

    Location of Telephone Connections:______________________________________________ Warranty For complete warranty information on this product please refer to the Limited Warranty Statement found on the website www.paradox.com/terms. Your use of the Paradox product signifies your acceptance of all warranty terms and conditions. Limitations of Alarm Systems We strongly advise that you review and take into consideration the “Limitations of Alarm Systems”...
  • Page 20 Printed in Canada - 07/2007 MGSP-EU08...

Table of Contents