UL AND C-UL INSTALLATION NOTES
This equipment is UL listed in accordance with standard UL1023 (Household Burglar -- Alarm Systems Units), standard UL985 (Household Fire Warning
Units) and standard CAN/C-UL S545 (Residential Fire Warning System Control Units). This equipment has the capability of being programmed with features
not verified for use in UL installations. To stay within these standards, the installer should use the following guidelines when configuring the system:
All components of the system should be UL listed for the intended application.
If the system will be used for "Fire" detection, the installer should refer to NFPA Standards #72, Chapter 2. In addition, once installation is
complete, the local fire authority must be notified of the installation.
This equipment must be verified by a qualified technician once every three years.
All keypads must use a tamper switch.
Maximum allowed entry delay is 45 seconds.
Maximum allowed exit delay is 60 seconds.
Minimum 4 minutes for bell cut-off time.
The following features do not comply with UL requirements: Bypass Recall, Shabbat and "No AC Fail" display.
Do not connect the primary indicating device to a relay. The installer must use the bell output.
The metallic enclosure that houses the Spectra control panel must be grounded to the cold water pipe.
Use a UL/C-UL listed Siren: Wheelock model# 46T-12.
Use a UL/C-UL listed 12Vdc 4Ah rechargeable battery: YUASA model# NP7-12.
Transformer requirements: UL listed transformer - 16VAC 40VA
The AUX, PGM and Keypad's maximum current cannot exceed 200mA for UL installations.
All outputs are Class 2 or power-limited, except for the battery terminal. The Class 2 and power-limited fire alarm circuits shall be installed using CL3, CL3R,
CL3P, or substitute cable permitted by the National Electrical Code, ANSI/NFPA 70.
The Seller warrants its products to be free from defects in materials and workmanship under normal use for a period of one year (unless otherwise
indicated). Except as specifically stated herein, all express or implied warranties whatsoever, statutory or otherwise, including without limitation, any implied
warranty of merchantability and fitness for a particular purpose, are expressly excluded. Because Seller does not install or connect the products and
because the products may be used in conjunction with products not manufactured by Seller, Seller cannot guarantee the performance of the security system.
Seller obligation and liability under this warranty is expressly limited to repairing or replacing, at Seller's option, any product not meeting the specifications. In
no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental, including
without limitation, any damages for lost profits, stolen goods, or claims by any other party caused by defective goods or otherwise arising from the improper,
incorrect or otherwise faulty installation or use of the merchandise sold.
© 2002-2003 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents
may apply: 5751803, 5721542, 5287111, 5119069, 5077549, Canadian and international patents may also apply. Spectra is a trademark or registered
trademark of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries.
UL and C-UL Warnings
UL listed Basler Electronics Transformer - #BE156240CAA
CSA listed Basler Electronics Transformer - #BE116240AAA
Warranty
Legal Notice
Spectra 1727 15