– Temperature Sensor: The communication with the temperature sen-
sor is faulty.
– FLASH EPROM: The communication with the permanent memory is
faulty. Configurations cannot be stored or read anymore.
– MAIN EPROM: The communication with the permanent memory is
faulty. Configurations cannot be stored or read anymore.
– Overheated: The system sets this alarm, if the system temperature is
higher than 57°C. Please disconnect the system from electricity or cool
down the ambient air temperature.
– DSP Module Access: The communication with the module is faulty.
– Ethernet MAC initialization: The initialization of the ethernet hard-
ware has failed.
TIP
You can also configure a system alarm as relay output (see PAGE 37).
• Under Application alarms all possible application alarms are displayed.
A red LED signals a currently existing alarm. It is also displayed how often
the alarm occurs since the unit has been switched on. You can reset the
alarm counter by pressing the Alarm Counter Reset button .
– DAB Decoder synced: This alarm occurs if the DAB decoder is not
synchronized. This alarm is only signalled if the decoded stream is a
DAB stream.
– DAB+ Decoder synced: This alarm occurs if the DAB+ decoder is not
synchronized. This alarm is only signalled if the decoded stream is a
DAB+ stream.
– DAB Decoder sampling clock: The DAB decoder receives a sampling
clock that doesn't correspond with the expected one. This alarm is only
signalled if the decoded stream is a DAB stream.
– ETI Framing: ETI framing cannot be found.
– TIST Signalling: The LI or NA TIST is not continiously.
– Audio Out level left: There is no signal on the left Audio output. This
alarm is only signalled if the audio level alarm is enabled (see CHAP-
TER 4.7.2.2.2, Page 44).
– Audio Out level right: There is no signal on the right Audio output.
This alarm is only signalled if the audio level alarm is enabled (see
CHAPTER 4.7.2.2.2, Page 44).
• Under AES/EBU status the following alarm can be displayed:
– AES3 Framing: This alarm is set, if the digital Audio output is used
with recovered clock and no digital input signal is available.
• Under 2-Mbit/s alarms all possible 2-Mbit/s (E1) alarms are displayed: A
red LED signals a currently existing alarm. It is also displayed how often
the alarm occurs since the unit has been switched on. You can reset the
alarm counter by pressing the Alarm Counter Reset button .
– No Signal: No 2-Mbit/s signal is received.
– No Sync: No 2-Mbit/s framing can be found.
– AIS (Alarm Indication Signal): Two or less „0" are received within the
last two frames. This alarm is only signalled if „G.704-NA" has been se-
lected as ETI format.