Restart (01H) - Prolific PL-6315 User Reference Manual

Binary message protocol
Table of Contents

Advertisement

2.1

Restart (01h)

Command
String
Length
Response
ACK
NAK
Description
Parameters
Restart Type
Start Mode
Year
Month
(UTC)
Day
Date &
Hour
Time
Minute
Second
Reserved
Latitude
(WGS-84)
Initial
Position
Longitude
Altitude
PL-6313 Product Datasheet
Restart (01h)
%%<F1h><01h>< Parameter Bytes><CS><CR><LF>
23
%%<06h><01h><CS><CR><LF>
%%<15h><01h><CS><CR><LF>
Force system to restart
Data (Range)
0: Hardware Reset (all parameters
below are unused)
1: Initialized Restart
When Restart type is Initialized
Restart
1: Hot start
2: Warm start
3: Cold start
4: Test start
5. Hot start with position
6. Warm start with time/position
7. Cold start with aided
Time/Position
>= 1980
1 ~ 12
1 ~ 31
0 ~ 23
0 ~ 59
0 ~ 59
-
Between – 9000 and 9000
> 0: North Hemisphere
< 0: South Hemisphere
Between – 18000 and 18000
> 0: East Hemisphere
< 0: West Hemisphere
Between –1000 and 18300
PL6315_Binary Message Protocol_v0.5.doc
Type
(Little-endian)
UNT08
UINT08
UINT16
UINT08
UINT08
UINT08
UINT08
UINT08
UINT08
SINT16
SINT16
SINT16
- 7 -
Revised Date:
July 21, 2009
Unit
Byte #
-
1
-
2
-
3 – 4
-
5
-
6
-
7
-
8
-
9
-
10
1/100
11 – 12
degree
1/100
13 – 14
degree
Meter
15 – 16
Document Version 0.3