Set Dop Mask (0Fh) - Prolific PL-6315 User Reference Manual

Binary message protocol
Table of Contents

Advertisement

2.14 Set DOP Mask (0Fh)

Command
String
Length
Response
ACK
NAK
Description
Parameters
DOP Mask Reference
GDOP Mask value
PDOP mask value
HDOP Mask value
PL-6313 Product Datasheet
Set DOP Mask (0Fh)
%%<F1h><0Fh>< Parameter byte><CS><CR><LF>
22
%%<06h><0Fh><CS><CR><LF>
%%<15h><0Fh><CS><CR><LF>
To set the DOP mask value and which type of DOP mask to use. When the
calculated DOP value is higher than this mask value, no valid position data will
be available.
Data (Range)
0: Disable DOP masking
1: Use GDOP
2: Use PDOP* (default)
3: Use HDOP
0 ~ 255
0 ~ 255
0 ~ 255
PL6315_Binary Message Protocol_v0.5.doc
Type
(Little-endian)
UINT08
UINT08
UINT08
UINT08
- 20 -
Revised Date:
July 21, 2009
Unit
Byte #
-
1
-
2
-
3
-
4
Document Version 0.3

Advertisement

Table of Contents
loading

Related Products for Prolific PL-6315

Table of Contents