2.17 1PPS Control (12h)

Command
String
Length
Response
ACK
NAK
Description
Parameters
Item
Pulse basic width
Multiplier
PL-6313 Product Datasheet
1PPS Control (12h)
%%<F1h><11h>< Parameter byte><CS><CR><LF>
10
%%<06h><12h><CS><CR><LF>
%%<15h><12h><CS><CR><LF>
Enable / disable 1PPS and setup pulse width and PPM signal.
-
1PPS signal is output when GPS satisfies the following condition at least 3
minutes.
Stationary state.
3D position fix.
-
Any interrupt on one of the conditions results in restarting the counter (3
minutes).
-
Pulse width = Pulse basic width x Multiplier
MMP field is used to define another signal output with 10us in width around
28~35us right after 1PPS.
Data (Range)
0: Disable
1: Pulse when lock
2: Always Pulse even lose lock
Bit[0..1]
0: 20 ms
1: 1 ms
2: 20 us
3: 1 us
Disable: signal type
Bit[2..7]: PPM period 1..60, 0:
disable
1 ~ 16 times,
for 1PPS only
PL6315_Binary Message Protocol_v0.5.doc
Type
(Little-endian)
UINT08
UINT08
UINT08
- 23 -
Revised Date:
July 21, 2009
Unit
Byte #
-
1
-
2
minute
-
3
Document Version 0.3