Set Nmea Configuration (04H) - Prolific PL-6315 User Reference Manual

Binary message protocol
Table of Contents

Advertisement

2.4

Set NMEA Configuration (04h)

Command
Set NMEA Configuration (04h)
%%<F1h><04h>< Parameter bytes><CS><CR><LF>
String
15
Length
Response
ACK
NAK
Description
Parameters
Configuration flag
RMC Interval
VTG Interval
GGA Interval
GSA Interval
GSV Interval
GLL Interval
ZDA Interval
PL-6313 Product Datasheet
%%<06h><04h ><CS><CR><LF>
%%<15h><04h ><CS><CR><LF>
Define the output interval between two consecutive NMEA sentences of the same
type. When all values are set to 0, no NMEA message is output.
Configuration flag contains decimal digits for position and time
Data (Range)
Bit7:0: Disable, 1:Enable,
Bit[0..2]: Position digits
Bit[3..5]: Time digits
0 ~ 255, 0: Disable
0 ~ 255, 0: Disable
0 ~ 255, 0: Disable
0 ~ 255, 0: Disable
0 ~ 255, 0: Disable
0 ~ 255, 0: Disable
0 ~ 255, 0: Disable
PL6315_Binary Message Protocol_v0.5.doc
Type
(Little-endian)
UINT08
UINT08
UINT08
UINT08
UINT08
UINT08
UINT08
UINT08
- 10 -
Revised Date:
July 21, 2009
Unit
Byte #
-
1
Second
2
Second
3
Second
4
Second
5
Second
6
Second
7
Second
8
Document Version 0.3