2.7
Restore Factory Default (08h)
Command
String
Length
Response
ACK
NAK
Description
Parameters
Restoration Key
PL-6313 Product Datasheet
Restore Factory Default (08h)
%%<F1h><08h>< Parameter bytes><CS><CR><LF>
11
%%<06h><08h><CS><CR><LF>
%%<15h><08h><CS><CR><LF>
Restore all configurable settings to factory default value.
All user settings will be erased.
Data (Range)
0x53434C50
PL6315_Binary Message Protocol_v0.5.doc
Type
(Little-endian)
UINT32
- 13 -
Revised Date:
July 21, 2009
(for 2C PL-6315)
Unit
Byte #
-
1 - 4
Document Version 0.3