Set Local Time (19H) - Prolific PL-6315 User Reference Manual

Binary message protocol
Table of Contents

Advertisement

2.23 Set Local Time (19h)

Command
String
Length
Response
ACK
NAK
Description
Parameters
Flag
Time Zone
Hour
(GMT+-)
Time Zone
Minute
(GMT+-)
Time Zone
Second
(GMT+-)
Adjust
PL-6313 Product Datasheet
Set Local Time (19h)
%%<F1h><19h>CS><CR><LF>
12
%%<06h><19h><CS><CR><LF>
%%<15h><19h><CS><CR><LF>
Set up user local time information. This command is useful to instruct module
to output time information based on used zone.
When flag is set to 0, system time is equal to UTC time.
When flag is set to 1, system time is adjusted to local time
Data (Range)
0: only local time is affected (e.g.
ZDA sentence)
1: both local and system time are
affected (e.g. GGA sentence)
-12 ~ +12
-59 ~ +59
'sign' should be the same as used
for Hour
-59 ~ +59
'sign' should be the same as used
for Hour
Normal: 0
For Daylight Saving Time or
Summer Time
PL6315_Binary Message Protocol_v0.5.doc
Type
(Little-endian)
UINT08
SINT08
SINT08
SINT08
SINT08
- 29 -
Revised Date:
July 21, 2009
Unit
Byte #
-
1
Hour
2
Minute
3
Second
4
Hour
5
Document Version 0.3

Advertisement

Table of Contents
loading

Related Products for Prolific PL-6315

Table of Contents