Read Trace Log (1Eh) - Prolific PL-6315 User Reference Manual

Binary message protocol
Table of Contents

Advertisement

2.27 Read Trace Log (1Eh)

Command
String
Length
Response
ACK
NAK
88h
D4h
Description
Parameters
Action
Baud rate
Port
* Need special H/W
PL-6313 Product Datasheet
Read Trace Log (1Eh)
%%<F1h><1Eh>< Parameter bytes><CS><CR><LF>
10
%%<06h><1Eh ><CS><CR><LF>
%%<15h><1Eh ><CS><CR><LF>
Packed trace record (See output message 88h)
Extended trace record (See output message D4h)
Start/stop reading the trace log.
A NAK message is returned when system is in recording. When logged records
are outputting, the normal position messages (NMEA/Binary) are temporarily
disabled until reading stops.
Data (Range)
0: stop,
1: Read packed trace record
0: 4800
1: 9600
2: 19200
3: 38400
4: 57600
5: 115200
0 = RS232 COM 1
PL6315_Binary Message Protocol_v0.5.doc
Type
(Little-endian)
UINT08
UINT08
UINT08
- 33 -
Revised Date:
July 21, 2009
Special HW required
Unit
Byte #
-
1
-
2
-
3
Document Version 0.3

Advertisement

Table of Contents
loading

Related Products for Prolific PL-6315