16
en | Introduction
3.3

Performance Characteristics

Notice!
If an external power supply is used, this should also guarantee
an uninterruptable power supply (UPS). Example: Bosch power
supply APS-PSU-60 (F.01U.282.970).
3.4

System Overview

The AMC2-4WE is connected between the access controller
AMC2-4W and the various peripheral devices.
2016-11 | AMC2-4WE |
Controlled by an AMC2 via RS-485
Reader interfaces
four Wiegand interfaces
Eight relay outputs
voltage free, power is supplied externally (dry mode)
powered by internal power supply (wet mode)
Eight analog inputs with internal power supply
Transfer rate to the extension interface: 9,6 kBit/s
Self regulating transmit/receive switching
Power supply:
10V - 30Vdc - max. 5 A
or over the RS-485 host connector
Information about the inputs and outputs on the display of
the AMC2 controller
Tamper contact for external covers
AMC2 Wiegand
Bosch Sicherheitssysteme GmbH
Extension