Siemens Sinamics S120 Getting Started page 53

Sinamics series
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

3. Activate the check box " S120_CU320_2_DP ", and click on "OK."
4. Click on the "Close" button.
5. Select the drive object "S120_CU320_2_DP" in the project navigator.
6. With the right mouse button, select the shortcut menu "Target device > Restore factory
7. Confirm the query with "OK".
8. Select the drive unit in the project navigator and go to the shortcut menu "Target device >
Getting Started
Getting Started, (GS1) 04/2014, 6SL3097-4AG00-0BP3
The PG/PC establishes the link to the Control Unit. It then performs an "Online/offline
comparison". The result is displayed in the following dialog "Online/offline comparison".
Example:
Figure A-2
Online/offline comparison
settings."
The PG/PC sets the drive parameters to their factory settings.
The new status is automatically transferred to the Control Unit memory card using the
function "Copy RAM to ROM".
Copy RAM to ROM."
The factory settings have now been restored: the drive is in a defined basic state.
Appendix
A.2 Restoring factory settings
53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents