1.4 Auto Power OFF Setting Tool
This tool is required only for products satisfy 2 conditions below. There is no need to
use this tool with products don't satisfy those conditions.
* Always use this tool after using the serviceman software tool on the machine.
Performing in wrong order would cause invalid auto power OFF setting in the product.
<Conditions>
1) Part code of the mounted main PCB ASSY is: LBC102001 (TD-4000), or
LBC103001 (TD-4100N).
2) Model code of the product is listed in table below.
TD-4000
TD-4100N
1.4.1
Role of the Auto Power OFF Setting Tool
This tool sets auto power OFF time on products with Erp-Tier2 compliant PCB for
particular destinations.
1.4.2
How to Use Auto Power OFF Setting Tool
(1) Connect the machine to your PC with the USB cable and turn ON the machine.
(2) When there is not a driver in your PC, "Found New Hardware Wizard" screen
appears. Install the driver as it is required for this tool.
Model
Model Code
E70728
U62664
E70372
E70908
E70730
U62665
Destination
AUS
ARG
CHN
IND
AUS
ARG
1 - 23