1.4.1. Installation rules
PPH 308 using solvented paints with a resistivity ρ
1
2
1
A
S
x
WARNING : All the conductive components must be connected to the ground potential (metal-
lic fittings of Moduclean, gear pump,etc...).
1
GNM 200- control module (out of the ATEX area)
2
Low voltage connection
3
-
4
-
5
Supplies of paint and rinsing products peinture connected to the ground potential.
6
Dump return line connected to the ground potential
7
Fittings paint/ rinsing and dump return connected to the ground potential into the atomizer
8
High voltage unit UHT 155 EEx em
Safety distance (area around the atomizer head from the parts with high voltage,
9
outer cover, bellcup, etc...)
WARNING : The installation of any system that does not comply with the rules specified above
and below is strictly prohibited.
Index revision : F - November 2017
2
5
5
S: Rinsing product
A: Air supply
1: Paint 1 supply
2: Paint 2 supply
Paint resistivity ρ
≥
6MΩ.cm:
8
7
6
≥
6 MΩ.cm
9
9
7012