1.5.14. Safety devices

During installation of the PPH 308, it is important to set up safety devices enabling high voltage
power, paint, solvent and air supplies to be cut immediatly if there is a problem.
• Detection of control system faults
• Detection of high voltage surges linked with the SAMES KREMLIN high voltage module.
• Detection of air pressure drops.
• Detection of ventilation failure.
• Detection of fire
• Detection of human presence.
• Detection of turbine rotation speed faults.
Failure to install safety devices could result in a risk of fire, expose the personnel to serious injury
and damage the equipment.

1.5.15. Mechanical Collision

The guarantee does not cover damage resulting from the operating environment (for example
collision with the robot).

1.5.16. Ambient Temperature

The sprayer is designed to work normally under room temperature between 0°C and + 40°C.
In order to optimise application quality, it is advised to work under room temperature between
+ 15°C and + 28°C.
The storage temperature will never exceed +60°C.

1.5.17. Sound level

The accoustic pressure level, continuous, equivalent, weighted, equals to 59,7 dBA.
Conditions of measurement:
The equipment has been run at its maximum values, the measures have been made from the
operator desk of the paint test booth "API" (closed booth with glass walls) of the Research & Ino-
vation laboratory at SAMES KREMLIN Meylan France.
Method of measurement:
The accoustic pressure level, continuous, equivalent, weighted (59,7 dBA) is given in LEQ value,
measured for observation periods of at least 30 seconds.

1.5.18. Specific maintenance provisions

The access of the booth, near the atomizer in operation, will have to be proscribed and con-
trolled by safety devices
of intrusion of people in the area.
Nevertheless, for maintenance operation, these safety devices will have to be arranged in
order to allow certain operations and checks (only for persons trained by SAMES KREMLIN).
The turbine rotation with a bellcup, in all the cases, wil be prohibited with personnel in the area
Index revision : F - November 2017
(see § 1.5.14 page
13) which will have to stop the equipment in case