Weighing equipment (Optional equipment)
176
The dead load selector
The dead load selector, located in the scale unit,
19
is used for setting the machine's "dead load".
The dead load is the load (weight) to which the
load cells are subjected before any load is pla-
ced in the wash drum. The dead load selector is
set before the machine leaves the factory, and its
setting should not normally be changed. For this
machine the selector should be set to
1000-1400 kg for W4400H, 2100-2550 kg for
W850H, W1100H and 1200-1600 kg for
W600H.
If calibration of the weighing equipment should
fail, one possible cause can be that this selector
is incorrectly set.