W465H, W475H/S, W485S, W4105H/S,
W475N/S, W485N/S, W4105N/S, W4130N/S
W4180N/S
W4250N/S
W4330N/S
Installation manual in original language
Installation manual
Washer extractors
W4130H/S, W4180H/S, W4240H,
W4250S, W4300H, W4330S
Type W3...
Clarus Control
From machine No.
00521/402183-
00650/107384-
00725/105494-
00795/102510-
438 9037-41/EN
2014.03.14

Advertisement

Table of Contents
loading

Summary of Contents for Electrolux W465H

  • Page 1 Installation manual Washer extractors W465H, W475H/S, W485S, W4105H/S, W4130H/S, W4180H/S, W4240H, W4250S, W4300H, W4330S Type W3... Clarus Control From machine No. W475N/S, W485N/S, W4105N/S, W4130N/S 00521/402183- W4180N/S 00650/107384- W4250N/S 00725/105494- W4330N/S 00795/102510- 438 9037-41/EN Installation manual in original language 2014.03.14...
  • Page 3: Table Of Contents

    Contents Contents Safety Precautions ..................5 Technical data ....................7 Installation H-model .................13 Transportation and unpacking, W465H, W475H, W4105H ....13 Transportation and unpacking, W4130H-W4300H ......14 Siting and floor ..................15 Mechanical installation ................16 Installation S-model .................17 Siting ....................17 Floor .....................17 Casting a plinth ..................18 Installation on an excisting floor or foundation........20...
  • Page 5: Safety Precautions

    Safety Precautions Safety Precautions The machine is only intended for water-wash use. Only use detergent intended for water-wash of textiles. Never use dry cleaning agents. Do not allow minors to use the machine. Do not hose down the machine with water. The machine's door lock must under no circumstances be bypassed.
  • Page 7: Technical Data

    Technical data Technical data W465H W475H W4105H W4130H W4180H W4240H W4300H Innerdrum volume litres diameter Drum speed wash extraction 1100 1100 1025 Heating electricity 5.4/5.6/7.5 5.4/5.6/7.5 5.6/7.5/10 steam hot water G-factor Weight, net Sound pressure level dB (A) Connections W465H...
  • Page 8 Technical data Technical data W475S W485S W4105S W4130S W4180S W4250S W4330S Innerdrum volume litres diameter Drum speed wash extraction 2.0/3.0/ 2.0/3.0/ 3.0/5.6/ 3.0/ 4.8/9.3 Heating 5.4/5.6/7.5 5.4/5.6/7.5 6.5/7.5/10 7.5/10 electricity steam hot water G-factor Weight, net Sound pressure level 63/59 63/59 63/64 70/64...
  • Page 9 Steam connection Drain Liquid detergent supply Control panel Soap box Door opening, W465H, W475H: ø 310, W4105H: ø 365, W4130H: ø 395, W4180H, W4240H, W4300H: ø 435 W465H 720 690 1115 355 1030 220 1010 135 100 240 – 720 690 1115 355...
  • Page 10 Technical data Electrical connection Cold water Hot water Steam connection Drain Liquid detergent supply Control panel Soap box Water reuse Door opening, W475S, W485S: ø310, W4105S, W4130S: ø365, W4180S: ø395, W4250S, W4330S: ø435 W475S 690 1115 355 45 1030 215 1010 130 W485S 730 1115 355 45 1030 215 1010 130...
  • Page 11 Technical data W465H W475H W4105H W4130H W4180H W4240H W4300H Frequency of the dynamic force 18.3 18.3 17.1 16.3 15.5 14.8 13.7 Floor load at max extraction 1.8±0.5 1.9±0.5 2.5±0.5 3.1±0.5 4.2±1.0 5.2±1.0 6.2±1.3 W475S W485S W4105S W4130S W4180S W4250S W4330S...
  • Page 13: Installation H-Model

    Installation Installation H-model Transportation and unpacking, W465H, W475H, W4105H The machine is delivered complete with expan- der bolts etc. packed inside the machine in the drum. The machine is delivered bolted onto the trans- port pallet and packed in a crate or box.
  • Page 14: Transportation And Unpacking, W4130H-W4300H

    Installation Transportation and unpacking, W4130H, W4180H, W4240H, W4300H The machine is delivered complete with expan- der bolts etc. packed inside the machine in the drum. The machine is delivered bolted onto the transport pallet and packed in a crate or box. • Remove packing from the machine.
  • Page 15: Siting And Floor

    Installation Siting and floor Install the machine close to a floor drain or open drain. In order to make installation and servicing the ma chine easier the following clearances are recommended: • At least 500 mm between the machine and the wall behind • and min. 50 mm on both sides of the machine whether installed next to the wall or other machines.
  • Page 16: Mechanical Installation

    Installation Mechanical installation • Mark and drill 2 holes (ø 8 mm) about 40 mm deep (W465-W4105) and ø 10 mm and 50 mm deep (W4130-W4300) in the positions shown. W465H 495 460 110 130 375 170 40 100 W475H 495 460 110 130 375 170 40 100 W4105H 575 465 130 140 455 185 35 W4130H 635 490 135 175 515 195 60 110...
  • Page 17: Installation S-Model

    Installation Installation S-model Leave the machine on the tran s port pallet until it can be placed in the final, pre pared position. Siting Install the machine close to a floor drain or open drain. In order to make installation and servicing the machine easier the following clearances are recommended: • At least 500 mm between the machine and...
  • Page 18: Casting A Plinth

    Installation Casting a plinth A plinth should be used where the existing floor is less than 100 mm thick or in order to ensure that the machine is above the level of any water leakages. The plinth should be approximately 150 - 200 mm in height.
  • Page 19 Installation S-models NOTE! For above models, two expander bolts must also be fitted to the front section of the machine. If not, large vibrations in the machine cabinett may occur. • Drill two holes (1) ø10 mm and 40 mm deep. • After the machine has been placed over the other four bolts, place the two spacer washers over the two holes. They shall be placed between the machine and foundation. • Mount the expander bolts in the drilled holes. Fit the washers and nuts, and tighten well. W475S 685 660 495 395 115 635 W485S 725 660 495 445 115 665 495...
  • Page 20: Installation On An Excisting Floor Or Foundation

    Installation Installation on an excisting floor or foundation Instead of braking up the excisting floor or foun- dation, chemical bolts M16 can be used. A set of four HILTI HVU bolts can be ordered from our Spares Dept, part No. 471 6699-64. Mounting instruction 5917 • Drill ø 18 mm (11/16") to a depth of 125 mm...
  • Page 21: Installation On Vinyl Floor Coverings

    Installation Installation on vinyl floor coverings If chemical anchors are to be used, drill holes for the mounting points. Cut the flooring material around the washers (washers and sealant are supplied in installation kit). Apply sealant to the hole cut in the vinyl floor covering.
  • Page 22: Installation, Ships, Oil-Rigs Etc

    Installation Installation, ships, oil-rigs, etc Leave the machine on the tran s port pallet until it can be placed in the final, pre pared position. Siting Install the machine close to a deck drain or open drain. In order to make installation and servicing the machine easier the following clearances are recommended: Floor...
  • Page 23: Welding A Foundation

    Installation Welding a foundation A welded foundation shall be made where concrete foundation can not be made. In order to make installation and servicing the machine easier the following clearances are recommended: • At least 1000 mm between the machine and the wall behind. Machine frame � � Bolt M16x45 Washer 44/16.5x6 ���...
  • Page 24: Installing The Machine

    Installation Installing the machine To install the machine: • Remove the transport packaging • Remove the front panel. • Remove the machine from the transport pallet and locate it on the bolts. When the machine is lifted off the pallet: Make sure that the machine does not come down on the floor with either of the rear corners first.
  • Page 25: Water Connections

    Installation Water connections All intake connections to the machine are to be fitted with manual shut-off valves and filters, to facilitate installation and servicing. Water pipes and hoses should be flushed clean before installation. After installation hoses should hang in gentle arcs. All connectors present on the machine must be connected up.
  • Page 26 Installation Water type Water connection cold cold cold and cold cold and W465H W475H/S, cold cold/ W485S 5336 hot* * For detergent container. ** Extra water valve which can be used for hard water if soft water is connected to 1.
  • Page 27: Drain Connection

    Installation Drain connection Connect a 75 mm (3") (alt. 50 mm, 2" and only W465-W4105) pipe or rubber hose to the machine’s drain pipe, ensuring a downward flow from the machine. Avoid sharp bends which may prevent proper draining. The drainage pipe should be located over a floor drain, drainage channel or the like so that the distance between the outlet and the drain is at least 25 mm (1").
  • Page 28: Steam Connection

    Installation Steam connection The steam supply to the machine should be fit- ted with manual shut-off valves and filters to faci- litate installation and servicing. The connection hose must be of type ISO/1307- 1983 or equivalent. Connection size at filter: DN 15 (BSP 1/2").
  • Page 29: Connection Of External Liquid Supplies

    Installation Connection of external liquid supplies Electrical installation must be carried out by an authorized personnel! All optional equipment connected must be EMC-approved to EN 50081-1 or EN 50082- Distribution card A can be used to control exter- nal functions, output and input signals. Outputs (200-240V AC): 5331 X71:1,2 Signal "Door locked, program on"...
  • Page 30 Installation If more signals are required the machine can be equipped with a second distribution card B. Outputs (200-240V AC): Card B X75:1 0 V (common) X75:2 Liquid supply 5 X75:3 Liquid supply 6 X75:4 Liquid supply 7 X75:5 Liquid supply 8 X76:1 0 V (common) X76:2...
  • Page 31: Electrical Installation

    Installation Electrical installation Electrical installation must be carried out by an authorized personnel! 1NAC Machines with frequency-controlled motors can be incompatible with certain types of earth leakage circuit breaker. It is important to know that the machines are designed to provide a high level of personal safety, which is why items of external equipment such as earth leakage circuit breakers 5332...
  • Page 32 Installation Three-phase connection: Connect the earth, neutral and phase wires as shown in example ”3AC” and ”3N AC” in the figure. When the installation is completed, check: • that the drum is empty. • that the machine operates by turning on the mains switch, starting the machine and using RAPID ADVANCE to reach the spin cycle (see operations manual).
  • Page 33 Installation IMPORTANT 415V 3AC machines can be supplied with 380, 400 or 415V. 380-400V 415V 240V 1AC machines can be supplied with 220, 230 or 240V. In the machine there is a transformer pla- ced in the front control unit (under the top cover).
  • Page 34 Installation W465H Heating Voltage Total Fuse alternative alternative No heating 200 V 3 AC or Steam heating 208-240 V 1 AC El heating 200 V 3 AC 220-240 V 1 AC 220-240 V 1 AC 230/240 V 1 AC 220-240 V 1 AC...
  • Page 35 Installation W475H Heating Voltage Total Fuse alternative alternative No heating 100-120 V 1 AC or Steam 200 V 3 AC heating 208-240 V 1 AC El heating 200 V 3 AC 220-240 V 1 AC 220-240 V 1 AC 230/240 V 1 AC 240 V 1 AC 220-240 V 1 AC 220-240 V 1 AC...
  • Page 36 Installation W4105H Heating Voltage Total Fuse alternative alternative 200 V 3 AC No heating 208-240 V 1 AC or Steam heating 200 V 3 AC El heating 220-240 V 3 AC 240 V 1 AC 220-240 V 1 AC 220-240 V 1 AC 220-240 V 3 AC 220-240 V 3 AC 208-240 V 3 AC...
  • Page 37 Installation W4130H Heating Voltage Total Fuse alternative alternative 200 V 3 AC No heating or Steam 208-240 V 1 AC heating 200 V 3 AC El heating 220-240 V 1 AC 12.5 208-240 V 3 AC 11.8 220-240 V 3 AC 12.5 380-415 V 3N/3 AC 12.5...
  • Page 38 Installation W4180H Heating Voltage Total Fuse alternative alternative 200 V 3 AC No heating 208-240 V 1 AC or Steam heating 240 V 1 AC 12.9 El heating 200 V 3 AC 13.4 220-240 V 3 AC 11.1 220-240 V 3 AC 17.5 380-415 V 3N/3 AC 17.5...
  • Page 39 Installation W4300H Heating Voltage Total Fuse alternative alternative No heating 200 V 3 AC or Steam 208-240 V 1 AC heating El heating 240 V 1 AC 14.3 200 V 3 AC 15.6 220-230 V 3 AC 19.4 220-230 V 3 AC 13.3 240 V 3 AC 14.3...
  • Page 40: How To Convert Heating Elements From 3Ac To 1Ac

    Installation How to convert heating elements from 3AC to 1 AC (400-415V 3AC to 230-240V 1AC) on W465H, W475H and W4105H. • Take off isolator cover plate and front panel to expose heating ele- ments. • Remove the cables A. 400-415V 3AC �� �� �� 5835 • Take off wire L3 (A) from terminal L3 on isolator Q1 and from terminal 6 on heating relay K21. Take off wire L2 (B) from terminal L2 on isolator Q1 and reconnect it to terminal N (neutral) instead.
  • Page 41 Installation W475S, W485S Heating Voltage Total Fuse alternative alternative No heating 200 V 3 AC or Steam 208-240 V 1 AC heating El heating 220-240 V 1 AC 230/240 V 1 AC 220-240 V 1 AC 220-240 V 1 AC 200 V 3 AC 220-240 3 AC 230/240 V 3 AC...
  • Page 42 Installation W4105S Heating Voltage Total Fuse alternative alternative No heating 200 V 3 AC or Steam 208-240 V 1 AC heating El heating 220-240 V 1 AC 220-240 V 1 AC 220-240 V 1 AC 200 V 3 AC 200 V 3 AC 208-240 V 3 AC 220-240 V 3 AC 220-240 V 3 AC...
  • Page 43 Installation W4130S Heating Voltage Total Fuse alternative alternative 200 V 3 AC No heating 208-240 V 1 AC or Steam heating 220-240 V 1 AC El heating 220-240 V 1 AC 220-240 V 1 AC 230/240 V 1 AC 208-240 V 1 AC 200 V 3 AC 200 V 3 AC 208-240 V 3 AC...
  • Page 44 Installation W4180S Heating Voltage Total Fuse alternative alternative 200 V 3 AC No heating 208-240 V 1 AC or Steam heating 220-240 V 1 AC 12.7 El heating 200 V 3 AC 220-240 V 3 AC 12.7 380-415 V 3/3N AC 12.7 440/480 V 3 AC 13.8...
  • Page 45 Installation W4330S Heating Voltage Total Fuse alternative alternative 208-240 V 1 AC No heating 200 V 3 AC or Steam heating 240 V 1 AC 14.7 El heating 200 V 3 AC 15.8 220-230 V 3 AC 13.5 220-230 V 3 AC 19.7 240 V 3 AC 14.6...
  • Page 47: Function Checks

    Function checks Function checks Manual operation • Switch on the machine's main switch. • Open the manual valves for water and for steam if the machine has steam heating. In the operating manual, chapter "Manual operation", one can find how to operate the machine manually. • Check that the drum is empty and close the door. • Close the drain valve. • Operate the machine manually to fill with cold water, then hot water. Check that these water supplies are connected as they should be. • Start the motor on wash action, and check that the motor is revolving clockwise and anticlockwise alternately, as normal for wash action.
  • Page 48 Electrolux Laundry Systems Sweden AB 341 80 Ljungby, Sweden www.electrolux.com/laundrysystems Share more of our thinking at www.electrolux.com...