120
HEATING RELAY ON IF NOT HEATED
TEMPERATURE INCREASE ALLOWED
LEVEL EMPTY
LEVEL OVERFILL
PAUSE TEST LEVEL
PAUSE TEST TEMPERATURE
DEFAULT TEMPERATURE HYSTERIS
TEMPERATURE STEP IN COOL-DOWN 4 °C
DEFAULT LOW EXTRACT TIME
DEFAULT MEDIUM EXTRACT TIME
DEFAULT HIGH EXTRACT TIME
DEFAULT DRAIN TIME
DEFAULT DISTR. TIME
DO UNBALANCE MEASUREMENT
DRAIN OPEN DELAY
START EXTRACT TIME
1
4
7
HEATING RELAY ON IF NOT HEATED
TEMPERATURE INCREASE ALLOWED
LEVEL EMPTY
LEVEL OVERFILL
PAUSE TEST LEVEL
PAUSE TEST TEMPERATURE
DEFAULT TEMPERATURE HYSTERIS
TEMPERATURE STEP IN COOL-DOWN
DEFAULT LOW EXTRACT TIME
DEFAULT MEDIUM EXTRACT TIME
DEFAULT HIGH EXTRACT TIME
DEFAULT DRAIN TIME
DEFAULT DISTR. TIME
DO UNBALANCE MEASUREMENT
DRAIN OPEN DELAY
START EXTRACT TIME
1
4
7
Programme unit
Y
Y
90
200
0
-18 °C
4 °C
00:00
00:00
00:00
00:00
00:00
N
0:1
00:0
Use the numeric keys to
enter the value.
2
3
5
6
If you make a mistake while
8
9
entering digits:
Press ERASE.
0
When you have finished:
Press .
Y
Y
90
200
0
-18 °C
4 °C
Applies only to machines
4 °C
with frequency-controlled
00:00
motor.
00:00
00:00
00:00
00:00
N
0:1
00:0
Use the numeric keys to
enter the value.
2
3
5
6
If you make a mistake while
8
9
entering digits:
Press ERASE.
0
When you have finished:
Press .
Temperature step in cool-down
Here you determine the maximum reduction in
temperature per minute during the first stage of
cool-down.
How does cool-down work?
When creating a new wash program you can,
to prevent creasing of the load, use the COOL-
DOWN module to achieve controlled cool-down
of the water in the drum. The cool-down se-
quence is divided into two stages:
1 wash temperature to middle temperature
Throughout this stage the machine will monitor
the cool-down rate, to ensure it does not exceed
the limit value you are determining here. If the
rate set is exceeded, no water will be added
until the mean value is acceptable again.
2 middle temperature to final temperature
The rate of cool-down is not monitored during
this stage. The valve opens and shuts as you
have programmed it to do.
Temperature monitoring
Temp.
Final temperature
Default values, extraction time
Here you determine how long the machine will
extract at the speeds low, medium and high. Later
in this section you will find the instructions for
programming the actual speeds to be used for low,
medium, high and "turbo" extraction.
How an extraction sequence works:
In order to extract some of the water from the
load at lower speeds, the drum does not acce-
lerate to its highest speed immediately. Instead
it accelerates in several steps. This means that
the drum first accelerates to a low speed level,
remains at that for a certain time, then accele-
rates to a higher level, extracts at that speed for
a certain time, and so on until it reaches its final
(maximum) extraction speed. If you program a
low extraction speed, the number of steps at the
beginning of the extraction sequence may be
reduced.
Speed
high
medium
low
Middle temperature
Time
Time