Locate Your Service Tag

Your storage system is identified by a unique service tag and Express Service Code.
The Service Tag and Express Service Code are found on the front of the system by pulling out the information tag. Alternatively, the
information might be on a sticker on the back of the storage system chassis. This information is used by Dell to route support calls to the
appropriate personnel.This information is used by the manufacturer to route support calls to the appropriate personnel.
NOTE:
The Quick Resource Locator (QRL) code on the information tag is unique to your system. Scan the QRL to get immediate
access to your system information using your smart phone or tablet.

Record System Information

Use the worksheet found in the appendix of this guide to record the information you will need to install the SCv3000 and SCv3020 storage
system.
Supported Operating Systems for Storage Center
Automated Setup
Setting up a Storage Center using the Discover and Configure Uninitialized Storage Centers wizard and the host setup wizards requires 64-
bit versions of the following operating systems:
Red Hat Enterprise Linux 6 or later
SUSE Linux Enterprise 12 or later
Windows Server 2008 R2 or later

Install and Use the Storage Manager Client

You must start the Storage Manager Client as an Administrator to run the Discover and Configure Uninitialized Storage Centers wizard.
1
Install the Storage Manager Client on a host server.
To discover and configure a Storage Center, the software must be installed on a host server that is on the same subnet as the storage
system.
2
To start the Storage Manager Client on a Windows computer, right-click on the Dell Storage Manager shortcut and select Run as
administrator. To start the Storage Manager Client on a Linux computer, execute the command ./Client from the var/lib/
dell/bin directory.
3
Click Discover and Configure Uninitialized Storage Centers. The Discover and Configure Uninitialized Storage Centers wizard
appears.

Discover and Select an Uninitialized Storage Center

The first page of the Discover and Configure Uninitialized Storage Centers wizard provides a list of prerequisite actions and information
required before setting up a Storage Center.
Prerequisites
The host server, on which the Storage Manager software is installed, must be on the same subnet or VLAN as the Storage Center.
Temporarily disable any firewall on the host server that is running the Storage Manager.
Layer 2 multicast must be allowed on the network.
Make sure that IGMP snooping is disabled on the switch ports connected to the Storage Center.
Discover and Configure the Storage Center