Fixtures must be installed by a Qualified electrician in accordance with all
national and local electrical and construction codes and regulations.
3.1 Connection to the mains
For protection from electric shock, the fixture must be earthed!
The Robin ColorStrobe Lite is equipped with auto-switching power supply that automatically adjusts to any 50-
60Hz AC power source from 100-240 Volts.
Connect the fixture to the mains by means of the enclosed power cord
If you need to install other plug on the power cord, note that the cores in the power cord are coloured according
to the following table. The earth has to be connected!
If you have any doubts about proper installation, consult a qualified electrician.
Core (EU)
Brown
Light blue
Yellow/Green
Do not overload the supply line and the connecting leads.
Wiring and connection work must be carried out by a qualified staff!
3. Installation
Core (US)
Connection
Black
Live
White
Neutral
Green
Earth
6
Plug Terminal Marking
L
N
Need help?
Do you have a question about the ROBIN colorstrobe lite and is the answer not in the manual?
Questions and answers