Error Processing
Special I/O Unit Restart Bits

3-7-5 Troubleshooting

Analog Output Does Not
Change
Output Does Not Change
as Intended
Outputs are Inconsistent
64
Bits
C200HX/HG/HE
28100
28101
28102
28103
28104
28105
28106
28107
28108
28109
28110 (See note.)
28111 (See note.)
28112 (See note.)
28113 (See note.)
28114 (See note.)
28115 (See note.)
Note SR bits 28110 to 28115 cannot be used wit C200HE, C200HX/HG-
CPU3j-E/4j-E PCs.
If the error is not cleared even after turning the Special I/O Unit Restart Bit ON
and then OFF again, then replace the Unit.
The following tables explain the probable causes of troubles that may occur, and
the countermeasures for dealing with them.
Probable Cause
The output is not set for being
used.
The output hold function is in
operation.
The conversion value is set outside
of the permissible range.
Probable Cause
The output signal range setting is
wrong.
The I/O specifications of the output
device do not match those of the
Analog Output Unit (e.g., input
signal range, input impedance).
The offset or gain is not adjusted.
Probable Cause
The output signals are being
affected by external noise.
C200H/HS
AR 0100
Unit #0 Restart Bit
AR 0101
Unit #1 Restart Bit
AR 0102
Unit #2 Restart Bit
AR 0103
Unit #3 Restart Bit
AR 0104
Unit #4 Restart Bit
AR 0105
Unit #5 Restart Bit
AR 0106
Unit #6 Restart Bit
AR 0107
Unit #7 Restart Bit
AR 0108
Unit #8 Restart Bit
AR 0109
Unit #9 Restart Bit
---
Unit #A Restart Bit
---
Unit #B Restart Bit
---
Unit #C Restart Bit
---
Unit #D Restart Bit
---
Unit #E Restart Bit
---
Unit #F Restart Bit
Countermeasure
Set the output for being used.
Turn ON the Output Conversion
Enable Bit.
Set the data within the range.
Countermeasure
Correct the output signal range
setting.
Change the output device.
Adjust the offset or gain.
Countermeasure
Try changing the shielded cable
connection (e.g., the grounding at
the output device).
Section
3-7
Functions
Turning the Restart Bit
g
f
for any Unit ON and
U i ON
d
then OFF again
then OFF again
restarts that Unit.
restarts that Unit.
Page
50
52
39
Page
50
38
54
Page
44