Wiring The Faulty Alarm Contact; Cabling - Planet IGS-504HPT User Manual

Industrial gigabit switch with 4 port 802.3at poe+
Hide thumbs Also See for IGS-504HPT:
Table of Contents

Advertisement

2.1.5 Wiring the Faulty Alarm Contact

The faulty alarm contacts are in the middle of the terminal block connector as
the picture shows below. Inserting the wires, the Industrial Gigabit PoE+ Switch
will detect the fault status of the power failure, or port link failure (available for
managed model) and then forms an open circuit. The following illustration shows
an application example for wiring the faulty alarm contacts.
1
Faulty Alarm Contacts
1. The wire gauge for the terminal block should be in the range of
12 ~ 24 AWG.
2. Alarm relay circuit accepts up to 30V, max. 3A currents.
Note

2.1.6 Cabling

10/100/1000Base-T
All
10/100/1000Base-T
automatically support 1000Base-T, 100Base-TX and 10Base-T networks. Users only
need to plug a working network device into one of the 10/100/1000Base-T ports,
and then turn on the Industrial Gigabit PoE+ Switch. The port will automatically
runs in 10Mbps, 20Mbps, 100Mbps or 200Mbps and 1000Mbps or 2000Mbps after
the negotiation with the connected device.
100Base-FX/1000Base-SX/LX
The IGS-624HPT Industrial Gigabit PoE+ Switch has two SFP interfaces that
support 100/1000 dual speed mode (optional multi-mode/single-mode 100Base-
FX/1000Base-SX/LX SFP module) through DIP switch setting.
Cabling
Each 10/100/1000Base-T port uses RJ45 sockets -- similar to phone jacks -- for
connection of unshielded twisted-pair cable (UTP). The IEEE 802.3/802.3u/802.3ab
2
3
4
5
Fault
ports
come
with
6
The Faulty Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs
Auto-Negotiation
capability.
They
17