5.0 Installation & Setup
5.10 Hydraulic System Check
The Titan 265 is powered by a hydraulic system consisting of an electric motor coupled directly to a
hydraulic pump.
The hydraulic reservoir holds 5 gallons of hydraulic fluid. It is filled with Rykon 46 hydraulic fluid at
the factory but should be checked before operation. Remove the lower rear panel cover. Check the
sight gauge on the rear side of the hydraulic tank. Fluid should just be visible in the sight gauge
(Figure 11). Add fluid if necessary, but avoid overfilling. For more information about checking and
changing the hydraulic fluid, including a cross-reference chart of approved fluids, see the
Recommended Oils section on page 46 of this manual. When finished, replace the panel.
The hydraulic fluid should be checked weekly and changed AT LEAST ONCE-PER-YEAR or after
every 1,000 hours of operation.
5.11 Optional False Clamp Plate
To prevent marking on pressure sensitive jobs, a false clamp plate is available as an optional item for
your machine. This plate attaches to the bottom of the clamp. It is secured with (3) setscrews
located in holes on the lower front face of the clamp.