Symbol Definitions; Command And Response Table For Sis Commands; Input Selection - Extron electronics FOX SW8 MM User Manual

8-input fiber optic switcher
Table of Contents

Advertisement

Symbol Definitions

Symbols (variables), defined below, are used in the command and response table. The
symbols represent variables in the command and response table fields.
]
= Carriage return/line feed
}
= Carriage return (no line feed)
E
= <Escape> key (hex 1B)
W
= Can be used interchangeably with the
|
= Can be used interchangeably with the
X!
= Input
X@
= Mute/front panel lock status
X#
= Transceiver module status
X$
= Firmware version
X%
= Transceiver module status
X^
= Temperature
X&
= Reclocked target
X*
= Input reclocker rate

Command and Response Table for SIS Commands

Command Function

Input selection

NOTE:
The three command codes in the input selection commands and view input commands; !, &, and %; can be used interchangeably.
Select input
Select input
Select input
View input
View input
View input
Channel mute
WARNING:
Risk of serious physical injury: The channel mute command mutes the data on the switched output only. The output
continues to emit light. The mute function has no affect on the looped-through outputs.
Mute output
Unmute output
Show video mute status
Reclocking
Set reclocker mode
Example:
Show reclocker mode
Front panel security lockout (executive mode)
Lock front panel
Unlock front panel
Show lock status
Resets
Reset mute
Reset whole switcher
E
character
}
character
ASCII Command
Response
(Host to Unit)
(Unit to Host)
X!
X!
!
In
•All
X!
X!
&
In
•RGB
X!
X!
%
In
•Vid
X!]
!
X!]
&
X!]
%
]
1B
Vmt1
]
0B
Vmt0
X@]
B
X&
X*
X&
*
=
Rte
8*0=
Rte08*00
X&
X*]
=
]
1X
Exe1
]
0X
Exe0
X@]
X
E
}
]
ZZ
Zpz
E
}
]
ZXXX
Zpx
00 through 08 (00 = no input)
0 = off (unmuted/unlocked)
1 = on (muted/locked)
0 = no module installed
1 = multimode
2 = singlemode
v.vv
0 = no light input
1 = light input
nnnF = whole degree Fahrenheit
00 = global
00 = Bypass (no reclocking)
01 = 1.25 Gbps
Additional description
]
X!
Select input
]
X!
Select input
]
X!
Select input
X!
Input
is selected for output.
X!
Input
is selected for output.
X!
Input
is selected for output.
Blank data on switched output.
Output data on switched output.
Switched output mute status is
X*]
*
Set the reclocker mode for target
]
Set the output reclocker mode to bypass (do not reclock).
Inputs cannot be selected from the front panel.
Inputs can be selected from the front panel.
Front panel lock status is
Unmute the output.
Unmute the output, unlock the front panel, and select
input 1.
08 = output
02 = 2.125 Gbps
03 = 4.25 Gbps (default)
to output.
to output.
to output.
X@
.
X&
X*
to
.
X@
.
FOX SW8 • Remote Control