Communication Protocol
The data address of control and status parameters please refer to the following table.
Parameter
Address
Description
Control
1000H
command
Inverter status
1001H
Communication
2000H
setting
Status
3000H
parameters
3001H
3002H
3003H
3004H
3005H
3006H
3007H
3008H
3009H
300AH
300BH
300CH
300DH
300EH
300FH
3010H
3011H
3012H
Meaning of value
0001H: Forward
0002H: Reverse
0003H: JOG forward
0004H: JOG reverse
0005H: Stop
0006H: Coast to stop
0007H: Reset fault
0008H: JOG stop
0001H: Forward running
0002H: Reverse running
0003H: Standby
0004H: Fault
Communication Setting Range
(-10000~10000)
Note: the communication setting is the
percentage of the relative value
(-100.00%~100.00%). If it is set as
frequency source, the value is the
percentage of the maximum frequency
(P0.04). If it is set as PID (preset value
or feedback value), the value is the
percentage of the PID.
Output frequency
Reference frequency
DC Bus voltage
Output voltage
Output current
Rotation speed
Output power
Output torque
PID preset value
PID feedback value
Input terminal status
Output terminal status.
Input of AI1
Input of AI2
Reserved
Reserved
HDI frequency
Reserved
Step No. of PLC or multi-step
110
R/W
Feature
W/R
R
W/R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R