NPort S8000 Series
Turbo Ring 2
Now Active
Ring 1/2
Status
Master/Slave
1st/2nd Ring Port Status
Coupling Mode
Coupling Port status

Restart

Restart System

Go to Restart System under Restart and then click Restart to restart the NPort S8000. Ensure that you save
all your configuration changes before you restart the system or else these changes will be lost.
Indicate the in used communication protocol. It may be Turbo Ring, Turbo Ring
V2, RSTP, or none.
Healthy
The ring is operating normally
Break
The backup link is active in the Ring.
Indicate NPort S8000 is in the Master mode or Slave mode of the Turbo Ring 2.
Link down
No connection
Blocked
This port is connected to a backup path and the path is blocked
Forwarding
Normal transmission
Learning
Learning
Indicates current coupling mode
It may be None, Dual Homing, or Ring Coupling.
Indicate which port is used to be coupling port (port 1 to port 5). Available
when Ring Coupling in communication redundancy setting page is enabled