Daily Maintenance; Fueling; Hydraulic Fluid - Upright AB62 Operator's Manual

Aerial work platform serial numbers 1266 - current
Hide thumbs Also See for AB62:
Table of Contents

Advertisement

Daily Maintenance

D
M
AILY
AINTENANCE
F
U E L I N G
Stop the engine and turn off the key switch before re-fueling.
G
ASOLINE
1. Open the left turret cover, then open the fill cap.
2. Fill to capacity with unleaded gasoline only.
• Fuel tank full capacity is 159 liters (42 US gallons).
3. Install the cap.
D
IESEL
1. Open the left turret cover, then open the fill cap.
2. Fill to capacity with diesel motor fuel only, grade #1-D or #2-D.
Use distillate fuel only; do not use residual or blend.
• Fuel tank full capacity is 159 liters (42 US gallons).
3. Install the cap.
LPG (
OPTION
1. Unfasten the coupler from the LPG valve on the tanks.
2. Remove the LPG tanks from the machine and fill according to ASME, NFPA and local standards.
IMPORTANT: When using propane, use clean, water free liquid petroleum gas, preferably from a bulk storage tank.
W A R N I N G
!
If you smell propane, close the supply valve on both tanks immediately until you have located and
corrected the leak.
H
Y D R A U L I C
1. Open the turret cover and check the fluid level at the sight
gauge with the boom stowed and retracted; engine running or
stopped.
NOTE: Never add hydraulic fluid if the boom is elevated or extended.
2. If necessary, fill to capacity with clean ISO compatible hydraulic
fluid.
• Normal Temperature, above 0° C (32° F) __ ISO #46.
• Low Temperature, below 0° C (32° F) ____ ISO #32.
• Extreme Temperature, below -17° C (0° F) ISO #15.
3. Clean the area around the cap before opening.
4. Open the filler/breather cap to add hydraulic fluid.
5. Install the cap.
Page 14
)
!
F
L U I D
Figure 10: Hydraulic Fluid Tank
Hydraulic Fluid Filler Cap
Level Gauge
104044-001 AB62 Work Platform - Operator Manual
Figure 9: Fuel Tank
Fuel Cap

Advertisement