UGPS Installation Procedure

Use the following procedure to install the UGPS module and to verify operation.
Procedure 17 UGPS installation – external-powered
1
Pole mount or surface mount the GPS antenna following the installation
guidelines and specifications listed in this chapter.
2
For PMP 100/400/430/450 and PTP 100/200 series, configure (via web
management interface) the access points/backhaul masters to sync to received
GPS signal (via the timing port). Navigate to Configuration > General and set the
Sync Input to Sync to Received Signal (Timing Port/UGPS). Since the UGPS will
be configured with an external power source, set the UGPS Power value to
Disabled.
Figure 79 Configuring the sync input and disabling UGPS power - PMP
For PMP 320 series, configure (via web management interface) the access point
to sync to received GPS signal (via the AP's RJ-11 port). Navigate to
Configuration > Settings and set the Sync Source to UGPS and Serial Type to
uGPS.

Figure 80 Configuring the sync source - PMP 320 series