4.5.4 Address Assignment for Multiple Sensors

When installing a number of sensors, note that each sensing head must first be assigned a separate
polling (1 to 15). To do this, use the software supplied with the Smart model, and the HART/RS232
adapter:
TX
info@Raytek-Direct.com
The sensing heads are factory-programmed with "Polling Address 0"!
Install the software, see software manual.
Connect the HART/RS232 adapter to the RS232 interface of your computer.
Connect the Smart model which is to be programmed to the adapter. Use either the installation
with the external resistor or the alternative with the internal resistor.
For configuring the sensor, go to the <Sensor> <Sensor Setup> menu in the software.
Figure 12: Address assignment with external (left) and internal (right) resistor
Rev. O7 07/2017