3. When ready to retrieve data, press the NL116 Initiate Removal button to
remove the card. The LED will be red while the most-current data is
stored to the card and then turn green. Eject the card while the LED is
green.
4. Put in the clean card ("CF-B").
5. Use CardConvert to copy data from CF-A to PC and convert. The default
CardConvert filename will be TOA5_stationname_tablename.dat. Once
the data is copied, use Windows Explorer to delete all data files from the
card.
6. At the next card swap, eject CF-B and insert the clean CF-A.
7. Running CardConvert on CF-B will result in separate data files containing
records since CF-A was ejected. CardConvert can increment the filename
to TOA5_stationname_tablename_0.dat.
8. The data files can be joined using a software utility such as WordPad or
Excel.
CardConvert File
CF-A Record Numbers
TOA5_tablename.dat
0-100
TOA5_tablename.dat
TOA5_tablename.dat
1235-....
NL116 Ethernet and CompactFlash
CF-B Record Numbers
101-1234
®
Module
29