A)
Loosen NUT (1), then turn SCREW (2) until the INDEX MARKER (3) is aligned
with the correct index number as per the Burner Set-up chart, on page 12.
B)
Retighten the RETAINING NUT (1)
Zero and five are scale indicators only. From left to right, the first line is
NOTE:
5 and the last line 0.
Note: Pump pressure must be set at time of burner start-up. A pressure gauge is
attached to the PRESSURE PORT (8) for pressure readings.
CONNECTORS (5) are supplied with the burner for connection to either a single or a
two-pipe system. Also supplied are two ADAPTORS (3), two female 1/4" NPT, to adapt
oil lines to burner pipe connectors. All pump port threads are British Parallel Thread
design. Direct connection of NPT threads to the pump will damage the pump body.
Riello manometers and vacuum gauges do not require any adaptors, and can be safely
connected to the pump ports. An NPT (metric) adapter must be used when connecting
other gauge models.
TURBULATOR SETTING

OIL LINE CONNECTIONS

- 17 -
Two PIPE