BCM450 Hardware & Installation
 mounting hardware (either a rackmount shelf, a wallmount bracket
per unit or four rubber feet per unit)
 Phillips screwdriver #2
 flat blade screwdriver
 pliers
 antistatic grounding strap
 connecting tool
 surge protector (recommended)
 cables, 25-pair cable with RJ-21 connectors

Installing the BCM450 Unit in an Equipment Rack

You can install a BCM450 main unit in a standard 19-inch equipment rack
along with your other networking and telecommunications equipment. The
BCM450 expansion unit can also be installed in the same rack.
Note: When you install the main unit in a rack, do not stack units directly on
top of one another. Mounting brackets cannot support multiple units. Fasten
each unit to the rack with the appropriate mounting brackets.
1. Place the BCM450 main unit on a flat, clean surface.
2. Take the right rack mount bracket and align the screw holes between
the bracket and the BCM450.
3. Fasten the bracket to the BCM450 main unit using four screws
provided. Use only the screws supplied with the rack-mount bracket.
Other screws can damage the BCM450 main unit.
4. Repeat the procedure with the left rack-mount bracket.
16
NN40011-001 Issue 1.2 BCM450 Rls 6.0