90
en | DMS - Data Management System
Generally, all core system processes (except batch programs)
run with the master. If for particular reasons individual
processes were terminated, a restart of all master-dependent
processes can be initiated using the "Auto start" function. This
avoids having to restart the entire system.
The "Shut down" and "Quick shut down" options should not be
used as the access control system is terminated exclusively by
the BIS System Manager.
"Tracing" menu
Figure 10.10 "Tracing" menu
While the trace level of individual processes can be changed in
the Process Control window, here it is possible to make this
change for all processes in one step. "Level 0" displays only
error and warning messages, "Level 3," on the other hand,
displays all incoming and outgoing messages. However, this
does not cause changes in the default settings that are entered
in the process description file - the next time the system is
started, the default values will be used.
Additional functions in this menu are the opening and closing of
all console windows in one step.
10.2
Server Processes
10.2.1
Summary
Several processes are executed on the DMS server that are
essential for the functionality of the access control system.
F.01U.028.713 | V 2.3.0.1 | 2009.11
Installation manual
BIS 2.3 - Access Engine
Bosch Sicherheitssysteme GmbH