Installation Guideline - Daikin UATN60CGXY1 Technical Manual

Uatn-c series package air conditioner rooftop cooling only [50hz]
Table of Contents

Advertisement

Application Information

Installation Guideline

Safety Precautions
This manual provides the procedures of installation to ensure a safe and good standard of operation for the
air conditioner unit.
Special adjustment may be necessary to suit local requirements.
Before using your air conditioner, please read this instruction manual carefully and keep it for future reference.
This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for
commercial use by lay persons.
This appliance is not intended for use by persons, including children, with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
WARNING
● Installation and maintenance should be performed by
qualified persons who are familiar with local code and
regulation, and experienced with this type of appliance.
● All field wiring must be installed in accordance with the
national wiring regulation.
● Ensure that the rated voltage of the unit corresponds
to that of the name plate before commencing wiring
work according to the wiring diagram.
● The unit must be GROUNDED to prevent possible
hazard due to insulation failure.
● All electrical wiring must not touch the refrigerant
piping, or any moving parts of the fan motors.
● Confirm that the unit has been switched OFF before
installing or servicing the unit.
● Disconnect from the main power supply before
servicing the air conditioner unit.
● DO NOT pull out the power cord when the power is
ON. This may cause serious electrical shocks which
may result in fire hazards.
● Keep the indoor and outdoor units, power cable and
transmission wiring, at least 1m from TVs and radios,
to prevent distorted pictures and static. {Depending on
the type and source of the electrical waves, static may
be heard even when more than 1m away}.
IMPORTANT
ENGLISH
Important information regarding the refrigerant
used
This product contains fluorinated greenhouse gases. Do
not vent gases into the atmosphere.
Refrigerant type:
R410A
GWP
value:
2087.5
(1)
GWP = global warming potential
(1)
The refrigerant quantity is indicated on the unit name
plate. Periodical inspections for refrigerant leaks may
be required depending on European or local legislation.
Please contact your local dealer for more information.
Disposal Requirement
Dismantling of the unit, treatment of the refrigerant, oil and other parts must be done in accordance with the applicable
legislation.
8
SAFETY PRECAUTIONS
Please take note of the following important points
when installing.
● Do not install the unit where leakage of flammable
gas may occur.
● Ensure that drainage piping is connected properly.
● Do not overcharge the unit.
● Ensure that the unit's panel is closed after service
or installation.
● Sharp edges and coil surfaces are potential
locations which may cause injury hazards. Avoid
from being in contact with these places.
● Before turning off the power supply, set the remote
controller's ON/OFF switch to the "OFF" position
to prevent the nuisance tripping of the unit. If this is
not done, the unit's fans will start turning automatically
when power resumes, posing a hazard to service
personnel or the user.
● Do not operate any heating apparatus too close to the
air conditioner unit.
● Don't use joined and twisted wires for incoming
power supply.
● The equipment is not intended for use in a potentially
explosive atmosphere.
Used only NITROGEN for air tight test.
Strictly do not charge OXYGEN or ACETYLENE into the
unit for any purpose.
NOTICE
CAUTION
If gas leaks and accumulates around the unit,
it may cause fire ignition.
If the drainage piping is not connected
properly, it may cause water leakage which
will dampen the furniture.
This unit is factory pre-charged.
Overcharge will cause over-current or damage
to the compressor.
Unsecured panels will cause the unit to
operate noisily.