Lyric Gateway Installation and Reference Guide
Programming Section
Programming Section
Programming Section
Programming Section
Installation and Setup Guide or Programming Guide
Installation and
Setup Guide or Programming Guide
Installation and
Installation and
Setup Guide or Programming Guide
Setup Guide or Programming Guide
Reporter
Reporter
Reporter
Reporter
System
System
System
System
Area
Area
Area
Area
Zones
Zones
Zones
Zones
User Guide
User Guide
User Guide
User Guide
User Functions/
User Functions/
User Functions/
User Functions/
User Access
System Functions/
System Functions/
System Functions/
System Functions/
Testing the System**
* Combined Entry Delay and Alarm Report Delay (Abort Window) should not exceed 1 minute.
** Refer to the User Guide for procedures on Testing the System.

SIA Quick Reference Guide

SIA Quick Reference Guide
SIA Quick Reference Guide
SIA Quick Reference Guide
Feature
Feature
Feature
Feature
Exit Error
Not selectable
Recent Closing
Not selectable
Alarm Cancel
Enabled or Disabled
Number of
1 to 6 Reports
Reports (Swinger
shutdown)
Alarm Report
No Delay, 15, 30 and 45
Delay (Abort
seconds
Window)
Entry Delay # 1
None, 15, 30, 45, 60
and 90 seconds and 2,
3 or 4 minutes
Entry Delay # 2
None, 15, 30, 45, 60
and 90 seconds and 2,
3 or 4 minutes
Exit Delay
45, 60, 90 and 120
seconds
Restart Exit Time
Enabled or Disabled
Exit Warning
Not selectable
Auto Stay
Enabled or Disabled
Arming
Cross Zone Delay
30 seconds and 2
minutes (in 30 second
increments), 3 minutes
and 4 minutes
Fire Alarms
Zone Type "Fire with
Verification" must be
selected for Fire Zone
95
Duress
Duress Code is
Programmed by Master
User as User 48
System Test
System tests provided
as a User Function
Communications
While the system is in
Test mode, no alarm
reports are sent to the
Central Station
Range
Range
Range
Range
Shipping Default
Shipping Default
Shipping Default
Shipping Default
Enabled
Enabled
Enabled
2 Reports
30 seconds
30 seconds
30 seconds
60 Seconds
Yes (Enabled)
Yes (Enabled)
Yes (Enabled)
None (Disabled)
Disabled
Disabled
n/a
Disabled
- 38 -
SIA Requirement
SIA Requirement
SIA Requirement
SIA Requirement
Enabled
Enabled
Enabled
2 Reports
30 seconds*
30 seconds minimum
30 seconds minimum
45 seconds minimum
Enabled
Enabled
Enabled
Enabled and two zones
programmed
Disabled
Disabled
n/a
Disabled